Important: Select accessories against the indoor-unit family and model shown. Some accessories require an additional cable, casing, bracket or interface module. Always confirm the complete accessory combination before ordering or installation.

1. Quick selection guide

RangeNominal cooling rangePower optionsIndoor model family
Bulkhead2.5–5.0 kWSingle phaseKLAP
450 mm Deep Bulkhead2.5–5.0 kWSingle phaseKSLAP
Mid Static Slimline5.0–13.0 kWSingle phaseKMTAP
High Static7.1–16.0 kWSingle or three phaseKHTA / KHTB
Large High Static18.0–22.4 kWSingle or three phaseKHTA

2. System combinations and capacities

TypePowerRefrigerantSystem setIndoor unitOutdoor unitCool kWHeat kW
BulkheadSingle PhaseR32SET-ARTH09KLLAPARTH09KLLAPAOTH09KBTA2.53.2
BulkheadSingle PhaseR32SET-ARTH12KLLAPARTH12KLLAPAOTH12KBTA3.54.0
BulkheadSingle PhaseR32SET-ARTH18KLLAPARTH18KLLAPAOTH18KBTA5.06.0
450mm Deep BulkheadSingle PhaseR32SET-ARTH09KSLAPARTH09KSLAPAOTH09KBTA2.53.2
450mm Deep BulkheadSingle PhaseR32SET-ARTH12KSLAPARTH12KSLAPAOTH12KBTA3.54.0
450mm Deep BulkheadSingle PhaseR32SET-ARTH18KSLAPARTH18KSLAPAOTH18KBTA5.06.0
Mid Static SlimlineSingle PhaseR32SET-ARTH18KMTAPARTH18KMTAPAOTH18KBTA5.06.0
Mid Static SlimlineSingle PhaseR32SET-ARTH24KMTAPARTH24KMTAPAOTH24KBTA7.18.0
Mid Static SlimlineSingle PhaseR32SET-ARTH30KMTAPARTH30KMTAPAOTH30KBTA8.510.0
Mid Static SlimlineSingle PhaseR32SET-ARTH36KMTAPARTH36KMTAPAOTH36KBTA10.011.2
Mid Static SlimlineSingle PhaseR32SET-ARTH45KMTAPARTH45KMTAPAOTH45KBTA12.514.0
Mid Static SlimlineSingle PhaseR32SET-ARTH54KMTAPARTH54KMTAPAOTH54KBTA13.015.0
Mid Static Slimline High PerformanceSingle PhaseR32SET-ARTH24KMTAP-HPARTH24KMTAPAOTH24KCTA7.18.0
Mid Static Slimline High PerformanceSingle PhaseR32SET-ARTH30KMTAP-HPARTH30KMTAPAOTH30KCTA8.510.0
High Static Single Phase High PerformanceSingle PhaseR32SET-ARTH30KHTA-HPARTH30KHTAAOTH30KCTA8.510.0
High Static Single Phase High PerformanceSingle PhaseR32SET-ARTH36KHTA-HPARTH36KHTAAOTH36KCTA10.012.5
High Static Single Phase High PerformanceSingle PhaseR32SET-ARTH45KHTA-HPARTH45KHTAAOTH45KCTA12.515.0
High Static Single Phase High PerformanceSingle PhaseR32SET-ARTH54KHTA-HPARTH54KHTAAOTH54KCTA14.016.5
High Static Single Phase High PerformanceSingle PhaseR32SET-ARTH60KHTBARTH60KHTBAOTH60KCTA16.018.0
High Static Single PhaseSingle PhaseR32SET-ARTH24KHTAARTH24KHTAAOTH24KBTA7.18.0
High Static Single PhaseSingle PhaseR32SET-ARTH30KHTAARTH30KHTAAOTH30KBTA8.510.0
High Static Single PhaseSingle PhaseR32SET-ARTH36KHTAARTH36KHTAAOTH36KBTA10.011.2
High Static Single PhaseSingle PhaseR32SET-ARTH45KHTAARTH45KHTAAOTH45KBTA12.514.0
High Static Single PhaseSingle PhaseR32SET-ARTH54KHTAARTH54KHTAAOTH54KBTA14.015.5
High Static Single PhaseSingle PhaseR32SET-ARTH60KHTAARTH60KHTAAOTH60KBTA15.518.0
High Static Three PhaseThree PhaseR32SET-ARTH36KHTA-3PHARTH36KHTAAOTH36KRTA10.011.2
High Static Three PhaseThree PhaseR32SET-ARTH45KHTA-3PHARTH45KHTAAOTH45KRTA12.514.0
High Static Three PhaseThree PhaseR32SET-ARTH54KHTA-3PHARTH54KHTAAOTH54KRTA14.015.5
High Static Three PhaseThree PhaseR32SET-ARTH60KHTA-3PHARTH60KHTAAOTH60KRTA15.518.0
Large High Static Single PhaseSingle PhaseR32SET-ARTH65KHTAARTH65KHTAAOTH65KBTA18.020.0
Large High Static Three PhaseThree PhaseR32SET-ARTH65KHTA-3PHARTH65KHTAAOTH65KRTA18.020.0
Large High Static Three PhaseThree PhaseR32SET-ARTH72KHTA-3PHARTH72KHTAAOTH72KRTA20.022.4
Large High Static Three PhaseThree PhaseR32SET-ARTH90KHTA-3PHARTH90KHTAAOTH90KRTA22.425.0
High-performance sets: The indoor model may be the same as the standard set, while the outdoor unit changes from the KBTA series to the higher-performance KCTA series. Order using the complete SET model shown.

3. Controllers and control options

ModelDescription / suitability
UTY-RHRYTOptional simple controller, 2-wire communication, no mode control.
UTY-RNNYNOptional wired controller for ducted units excluding KLLAP and KSLAP models.
UTY-RNRTWired controller for KMTAP and KHTA/KHTB models.
UTY-RNRYT5Optional touch-screen controller.
UTY-RSNYNSimplified optional wired controller.
UTY-RSRYT1Optional simple controller, 2-wire communication; listed for AGTG and ABTH models.
UTY-RSRYTOptional simple controller, 2-wire communication.
UTY-RVNYNOptional backlit wired controller.
UTY-RVRYOptional wired Mirror Touch controller.

4. anywAiR and zoning accessories

ModelDescription / suitability
UTY-NXT-BOXanywAiR Technology Adapter II USB.
UTY-NXT-CABUART cable for anywAiR Technology Adapter II; required when installing UTY-NXT-BOX.
UTY-ANY2Ducted anywAiR controller suitable for high-static and KMTAP systems.
KIT-GD-ANYGarage-door and sensor kit.
ETH-ANY25 m Ethernet cable.
TS-ANYWireless wall sensor for anywAiR.
UTY-CDPXZC24 V zone-control interface module for ducted units excluding KLLAP/KSLAP.
UTY-CDPXZD240 V zone-control interface module for ducted units excluding KLLAP/KSLAP.
UTY-CDRXZC24 V zone-control interface module for KMTAP and KHTA/KHTB.
UTY-CDRXZD240 V zone-control interface module for KMTAP and KHTA/KHTB.
UTY-XSZXZ3030 m remote sensor for zone controller; suitable for UTY-CDRXZC or UTY-CDRXZD.
ZM-ANY8 / 10 / 12 / 14 / 1624 V opposed-blade dampers in 200, 250, 300, 350 and 400 mm sizes; cable included.
ZM-CABLE20BEIGEOptional 20 m cable for dampers.

5. Other accessories and interfaces

ModelCategoryDescription / suitability
UTD-GXTA-WIndoor accessoryAuto grille louvre kit for ARTH09/12 KLLAP/KSLAP.
UTD-GXTB-WIndoor accessoryAuto grille louvre kit for ARTH18 KLLAP/KSLAP.
UTD-LFDAIndoor accessoryLong-life filter for 30/36/45/54 KMTAP.
UTD-LFDBIndoor accessoryLong-life filter for 18/24 KMTAP.
UTD-LF60KAIndoor accessoryLong-life filter for 24/30/36/45 KHTA.
UTD-LFKAIndoor accessoryLong-life filter for 65/72/90 KHTA.
UTY-LBTYMIndoor accessoryIR receiver unit.
UTY-XCSXIndoor accessoryExternal input and output PCB for KLLAP/KSLAP, 54KMTAP and 65/72/90KHTA.
UTY-XSZXTIndoor accessoryRemote sensor with shield plate for ARTH65/72/90KHTA.
UTY-XSZXZ1Indoor accessoryRemote sensor unit.
UTY-XWZXZGIndoor accessoryExternal control wiring kit for KHTA/KHTB, KLLAP/KSLAP and KMTAP.
UTZ-GXDAIndoor accessoryExternal input/output PCB casing; required for KMTAP when installing UTY-XCSX.
UTZ-GXEAIndoor accessoryExternal input/output PCB casing; required for ARTH09/12/18 KLLAP/KSLAP when installing UTY-XCSX.
UTZ-GXNAIndoor accessoryExternal input/output PCB bracket for ARTH60/65/72/90 KHTA and 60KHTB.
UTZ-PX1NABIndoor accessoryOptional drain pump for ARTH60/65/72/90KHTA and 60KHTB.
UTY-VKSXGateway controlKNX converter for KHTA/KHTB, KMTAP and KLLAP/KSLAP.
UTY-VMSXGateway controlModbus converter for KHTA/KHTB, KMTAP and KLLAP/KSLAP.
UTY-TERXIndividual controlExternal switch controller, 2-wire only.
UTY-VTGXNetwork converterStandard-product connection, DC powered from indoor unit.
UTY-VTGXVNetwork converterStandard-product connection, AC powered.
UTP-FX06AOutdoor accessoryL-shape pipe kit for AOTH72/90KRTA.
UTY-XWZXZ2Outdoor accessoryExternal connect kit.
UTY-XWZXZ3Outdoor accessoryExternal connect kit for AOTH30/45/54/60/65/72/90 KBTA/KCTA/KRTA.
Ordering check: Confirm the full indoor model number, system set, controller requirements, zoning voltage and any mandatory accessory cable, casing or bracket before submitting the order.