Use this guide to identify the correct indoor and outdoor unit combination, power supply, refrigerant, included controller and available accessories.
Quick answer: Floor console systems are available from 2.5 kW to 4.2 kW cooling. Floor/ceiling systems are available at 5.2 kW cooling. Under-ceiling systems are available from 5.0 kW to 13.0 kW cooling in single-phase and selected three-phase combinations.
Important: Always order the complete matched system shown. Do not substitute indoor or outdoor units unless the alternative combination is confirmed in current product documentation.

1. System selection overview

System typeCooling rangePower supplyController arrangement
Floor Console2.5-4.2 kWSingle phaseWireless controller included
Floor/Ceiling5.2 kWSingle phaseWireless controller included
Under Ceiling5.0-13.0 kWSingle phase and selected three phaseWireless or wired set options

2. Floor console and floor/ceiling matched systems

TypeSystemIndoor unitOutdoor unitRefrigerantCoolHeatController
Floor ConsoleSET-AGTG09KVCAAGTG09KVCAAOTG09KVCAR322.5 kW3.5 kWWireless included
Floor ConsoleSET-AGTG12KVCAAGTG12KVCAAOTG12KVCAR323.5 kW4.5 kWWireless included
Floor ConsoleSET-AGTG14KVCAAGTG14KVCAAOTG14KVCAR324.2 kW5.2 kWWireless included
Floor/CeilingSET-ABTG18LVTAABTG18LVTAAOTG18LACCR410A5.2 kW6.0 kWWireless included

3. Under-ceiling matched systems

Wireless controller sets - UTY-LBTYH

PowerSystemIndoor unitOutdoor unitCoolHeat
Single phaseSET-ABTH18KRTA-YHABTH18KRTAAOTH18KBTA5.0 kW6.0 kW
Single phaseSET-ABTH24KRTA-YHABTH24KRTAAOTH24KBTA7.1 kW8.0 kW
Single phaseSET-ABTH30KRTA-YHABTH30KRTAAOTH30KBTA8.5 kW10.0 kW
Single phaseSET-ABTH36KRTA-YHABTH36KRTAAOTH36KBTA10.0 kW11.2 kW
Single phaseSET-ABTH45KRTA-YHABTH45KRTAAOTH45KBTA12.5 kW14.0 kW
Single phaseSET-ABTH54KRTA-YHABTH54KRTAAOTH54KBTA13.0 kW15.5 kW
Three phaseSET-ABTH36KRTA-3PH-YHABTH36KRTAAOTH36KRTA10.0 kW11.2 kW
Three phaseSET-ABTH45KRTA-3PH-YHABTH45KRTAAOTH45KRTA12.5 kW14.0 kW
Three phaseSET-ABTH54KRTA-3PH-YHABTH54KRTAAOTH54KRTA13.0 kW15.5 kW

Wired controller sets - UTY-RNRYT5

The indoor and outdoor combinations and capacities are the same as the wireless sets above. Select the -T5 system code where the UTY-RNRYT5 wired touch-screen controller is required.
PowerWired system codes
Single phaseSET-ABTH18KRTA-T5, SET-ABTH24KRTA-T5, SET-ABTH30KRTA-T5, SET-ABTH36KRTA-T5, SET-ABTH45KRTA-T5, SET-ABTH54KRTA-T5
Three phaseSET-ABTH36KRTA-3PH-T5, SET-ABTH45KRTA-3PH-T5, SET-ABTH54KRTA-3PH-T5

4. Compatible accessories and controls

Controllers

ModelDescription
UTY-RHRYTOptional simple controller, 2-wire communication, no mode control. Suitable for AGTG and ABTH models.
UTY-RNNYNWired controller suitable for ABTG models.
UTY-RNRYT5Optional touch-screen controller.
UTY-RSNYNSimplified optional wired controller suitable for all ABTG models.
UTY-RSRYT1Optional simple controller, 2-wire communication, suitable for AGTG and ABTH models.
UTY-RSRYTOptional simple controller, 2-wire communication, suitable for AGTG and ABTH models.
UTY-RVNYNOptional backlit wired controller.
UTY-RVRYOptional wired controller with mirror-touch interface.

Indoor and installation accessories

ModelDescription
UTY-NXT-BOXanywAiR Technology Adapter II USB.
UTY-NXT-CABUART cable for anywAiR Technology Adapter II. Required when installing UTY-NXT-BOX.
UTD-ECS5AWiring kit.
UTR-DPB24TCondensate pump for under-ceiling models.
UTY-LBTYHInfrared receiver kit.
UTR-STAHalf-concealed kit suitable for AGTG models.
UTY-XWZXExternal connect kit.
UTY-XWZXZ5External control wiring kit suitable for AGTG models.

Gateway, external control and network options

ModelDescription
UTY-VKSXKNX converter for indoor unit, suitable for AGTG and ABTH models.
UTY-VMSXModbus converter for indoor unit, suitable for AGTG and ABTH models.
UTY-TERXExternal switch controller, 2-wire only.
UTY-VTGXNetwork converter for standard product connection, DC powered from indoor unit.
UTY-VTGXVNetwork converter for standard product connection, AC powered.
Accessory compatibility: Suitability can vary by indoor-unit series and controller configuration. Confirm the applicable installation manual and interface requirements before ordering or installation.

5. Ordering checklist

  • Confirm the required unit type: floor console, floor/ceiling or under ceiling.
  • Select the required cooling and heating capacity.
  • Confirm whether the site requires single-phase or three-phase power.
  • Order the complete matched system code.
  • For under-ceiling systems, select either the wireless -YH set or wired touch-controller -T5 set.
  • Confirm accessory compatibility against the exact indoor-unit model.
Product combinations and accessories are based on the supplied selection tables. Confirm current availability, final model compatibility and installation requirements before supply.