GENERAL AIRSTAGE PRODUCT REFERENCE
ASTH30KMTD
Lifestyle Range • Wall Mounted • Reverse Cycle
Ideal for large rooms. With energy management features such as Human Sensor Control, economy mode, and weekly timers, the Lifestyle Next range with smart climate control makes indoor comfort easy and cost-effective.
Quick Summary
Indoor unitASTH30KMTD
Outdoor unitAOTH30KMTD
Product categoryWall Mounted
Product rangeLifestyle range
Capacity8.50kW Cooling 9.00kW Heating
Room sizeLarge Room
Operation typeReverse Cycle
RefrigerantR32
Technical Specifications
Indoor unitASTH30KMTD
Outdoor unitAOTH30KMTD
Operation TypeReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))8.50 (2.9 - 10.5)
Heating Capacity kW (Rated (Min - Max))9.00 (2.7 - 11.2)
Input Power Cooling kW (Rated (Min - Max))2.49 (0.6 - 4)
Input Power Heating kW (Rated (Min - Max))2.39 (0.48 - 3.6)
EER Cooling kW/kW3.41
COP Heating kW/kW3.77
Running Current amps (Cooling / Heating)11 / 10.6
Moisture Removal l/hr4.4
Indoor Sound Pressure Cooling dBA (High / Quiet)51 / 32
Indoor Sound Pressure Heating dBA (High / Quiet)48 / 32
Outdoor Sound Pressure dBA (Cooling / Heating)53 / 55
Outdoor Sound Power dBA65
Air Circulation (Indoor - High Fan) Cooling l/sec381
Air Circulation (Indoor - High Fan) Heating l/sec350
Seasonal Performance
Star Rating Cooling (0-10) (Hot / Average / Cold)4 / 3.5 / 4
Star Rating Heating (0-10) (Hot / Average / Cold)4 / 3 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.56 / 5.284 / 5.716
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.55 / 4.534 / 3.841
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)6.233 / 6.729 / 7.766
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.611 / 5.02 / 4.353
Dimensions, Piping and Operating Limits
Indoor Unit Dimensions mm (Height x Width x Depth)340 x 1150 x 280
Indoor Unit Weight kg16.50
Outdoor Unit Dimensions mm (Height x Width x Depth)788 x 940 x 320
Outdoor Unit Weight kg53.00
Piping Connects mm Ø (Liquid / Gas)9.52 / 15.88
Pipe Length m (Max (Precharged))50 (20)
Max Height Difference m30
Operation Range Cooling °CDB (Min to Max)-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24
Refrigerant TypeR32
Refrigerant Amount g1,700
Controls and Communication
UART CommunicationYes
UART Communication Port2 Ports - CN65, CN75
What Is Included
ASTH30KMTDIndoor Unit
AOTH30KMTDOutdoor Unit
AR-REW1EWireless Remote Controller
Optional Parts and Interfaces
UTY-NXT-BOXWiFi Control
UTY-RHRYTWired Remote Controller - Simple Controller Without Mode Button
UTY-RNRYT5Wired Remote Controller - Backlit Touch Panel Wall Controller
UTY-RSRYTWired Remote Controller - Simple Controller With Mode Button
UTY-RVRYWired Remote Controller - KAGAMI Wired Remote Controller
UTY-TWRXZ2Communication Kit
UTY-XCSXZ2External Input & Output PCB
UTY-XWZXZ5External Control Wiring Kit
Key Features
All DCWith All DC, electricity loss is decreased and power consumption reduced.
Apple-Catechin FilterFine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Auto RestartShould there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
Auto Shut LouvreThe auto shut louvres close or open automatically when the unit stops or starts.
Auto ChangeoverThe unit automatically switches between operating modes based on the temperature setting and room temperature.
Automatic Air Flow AdjustmentThe micro-processor automatically adjusts the air flow to follow changes in room temperature.
Automatic LouvreThe position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Auto-Off TimerAutomatically stops the units operation when a fixed time has elapsed from the start of operation.
Blue Fin Heat ExchangerCorrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
Demand ResponseThis product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.
Double Swing AutomaticComplex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.
Economy ModeLimits the maximum operation current, and performs operation with the power consumption suppressed.
Filter SignSelect appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
Human SensorHuman sensor detects movement of people within the conditioned room.
i-PAMi-PAM inverter technology enables high output and high efficiency performance.
Long-Life Ion Deodorisation FilterThe filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.
Low Noise ModeThe compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.
On-Off TimerON-OFF timer can be set to operate once every 24 hours.
Powerful ModePowerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.
Program TimerThis timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
Right / Left Swing LouvreThe right/left louvre automatically swings in either direction.
Sleep TimerThe micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Super Quiet ModeThe indoor units fan can operate at a low speed to produce quieter operation.
Up/Down Swing LouvreThe up/down louvre automatically swings up and down.
V-PAMv-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.
Washable PanelDust that accumulates on the air conditioner can be easily cleaned with a damp cloth.
Weekly TimerDifferent ON-OFF times can be set for up to 7 days.
10°C Heat OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
Manuals, Product and Reference Links
Product pageOpen link
Operating manualOpen link
Product brochureOpen link
Energy rating labelOpen link
Dimensions: Dimension drawingOpen link
Dimensions: Dimension drawingOpen link
Product information compiled from the GENERAL Australia product page. Confirm current specifications and compatibility before installation.