GENERAL AIRSTAGE PRODUCT REFERENCE
ASTH24KMTE
Lifestyle Range | Wall Mounted Reverse Cycle
Specifications, controls, included equipment, optional parts and key features
System combination
Indoor: ASTH24KMTE
Outdoor: AOTH24KMTE
Included controller: AR-REW1E wireless remote controller
Refrigerant: R32
Quick navigation
Quick SummarySpecificationsDimensionsControlsIncludedOptional PartsFeaturesOperating Manual
1. Quick summary
ItemDetail
Product categoryWall Mounted
Product rangeLifestyle range
Recommended room sizeMedium room
Operation typeReverse Cycle
Cooling capacity7.10 (1.1 - 8.3) kW
Heating capacity8.00 (1.1 - 10.1) kW
Power supply230 / 1 / 50 V/Ph/Hz
RefrigerantR32
2. Technical specifications
SpecificationValue
Indoor / outdoor unitASTH24KMTE / AOTH24KMTE
Cooling capacity7.10 (1.1 - 8.3) kW
Heating capacity8.00 (1.1 - 10.1) kW
Input power cooling2.2 (0.24 - 3.15) kW
Input power heating2.04 (0.14 - 3.17) kW
EER / COP3.23 / 3.92
Running current cooling / heating9.8 / 9.3 A
Indoor sound pressure cooling49 / 29 dBA (High / Quiet)
Outdoor sound pressure cooling / heating54 / 53 dBA
Air circulation cooling / heating325 / 331 L/s
Operating range cooling-10 to 50°C DB
Operating range heating-15 to 24°C DB
Refrigerant charge1,270 g R32
Maximum pipe length / precharge30 m / 15 m
Maximum height difference25 m
Seasonal performance
MetricHotAverageCold
Cooling star rating3.53.54
Heating star rating3.52.52
Residential TCSPF5.4295.2515.682
Residential HSPF5.2494.3453.603
Commercial TCSPF6.0416.9167.917
Commercial HSPF4.8695.4034.117
3. Dimensions and piping
ItemDetail
Indoor unit dimensions280 x 980 x 240 mm
Indoor unit weight12.50 kg
Outdoor unit dimensions716 x 820 x 315 mm
Outdoor unit weight41.00 kg
Piping – Liquid / Gas6.35 / 12.7 mm
4. Controls and communication
ItemDetail
UART communicationYes
UART communication port2 Ports - CN65, CN75
Included controllerAR-REW1E wireless remote controller
5. What is included
Included itemDescription
ASTH24KMTEIndoor unit
AOTH24KMTEOutdoor unit
AR-REW1EWireless remote controller
6. Optional parts and interfaces
ModelDescription
UTY-NXT-BOXWi-Fi control.
UTY-RHRYTWired remote controller – simple controller without mode button. Requires UTY-TWRXZ2 communication kit.
UTY-RNRYT5Wired remote controller – backlit touch-panel wall controller. Requires UTY-TWRXZ2 communication kit.
UTY-RSRYTWired remote controller – simple controller with mode button. Requires UTY-TWRXZ2 communication kit.
UTY-RVRYKAGAMI wired remote controller. Requires UTY-TWRXZ2 communication kit.
UTY-TWRXZ2Communication kit.
UTY-XCSXZ2External input and output PCB.
UTY-XWZXZ5External control wiring kit. Requires UTY-XCSXZ2 external input and output PCB.
7. Key features
FeatureDescription
All DCWith All DC, electricity loss is decreased and power consumption reduced.
Apple-Catechin FilterFine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Auto RestartShould there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
Auto Shut LouvreThe auto shut louvres close or open automatically when the unit stops or starts.
Auto ChangeoverThe unit automatically switches between operating modes based on the temperature setting and room temperature.
Automatic Air Flow AdjustmentThe micro-processor automatically adjusts the air flow to follow changes in room temperature.
Automatic LouvreThe position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Auto-Off TimerAutomatically stops the units operation when a fixed time has elapsed from the start of operation.
Blue Fin Heat ExchangerCorrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
Demand ResponseThis product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.
Double Swing AutomaticComplex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.
Economy ModeLimits the maximum operation current, and performs operation with the power consumption suppressed.
Filter SignSelect appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
Human SensorHuman sensor detects movement of people within the conditioned room.
i-PAMi-PAM inverter technology enables high output and high efficiency performance.
Long-Life Ion Deodorisation FilterThe filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.
Low Noise ModeThe compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.
On-Off TimerON-OFF timer can be set to operate once every 24 hours.
Powerful ModePowerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.
Program TimerThis timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
Right / Left Swing LouvreThe right/left louvre automatically swings in either direction.
Sleep TimerThe micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Super Quiet ModeThe indoor units fan can operate at a low speed to produce quieter operation.
Up/Down Swing LouvreThe up/down louvre automatically swings up and down.
V-PAMv-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.
Washable PanelDust that accumulates on the air conditioner can be easily cleaned with a damp cloth.
Weekly TimerDifferent ON-OFF times can be set for up to 7 days.
10°C Heat OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
8. Manuals and product links
ASTH24KMTE resources
Open operating manualOpen product pageOpen energy label
Product note: Confirm current accessory compatibility, controller requirements and installation details against the latest product page and technical manuals before ordering or installation.
GENERAL AIRSTAGE | ASTH24KMTE Product Reference