Product Information - ASTG24KMTC (SET-ASTG24KMTC)
Print
Modified on: Thu, 16 Jul, 2026 at 9:32 AM
GENERAL AIRSTAGE PRODUCT REFERENCE ASTG24KMTC Lifestyle Range | Wall Mounted Reverse Cycle Specifications, controls, included equipment, optional parts and key features | System combination Indoor: ASTG24KMTC Outdoor: AOTG24KMTC Included controller: AR-REW1E wireless remote controller Refrigerant: R32 |
| Quick navigation Quick SummarySpecificationsDimensionsControlsIncludedOptional PartsFeaturesOperating Manual | 1. Quick summary | | Item | Detail | | Product category | Wall Mounted | | Product range | Lifestyle range | | Recommended room size | Medium room | | Operation type | Reverse cycle | | Cooling capacity | 7.10 kW rated | | Heating capacity | 8.00 kW rated | | Power supply | 230 V / 1 Ph / 50 Hz | | Refrigerant | R32 |
| 2. Technical specifications | | Specification | Value | | Cooling capacity – Rated / Min–Max | 7.10 kW / 1.1–8.3 kW | | Heating capacity – Rated / Min–Max | 8.00 kW / 1.1–10.1 kW | | Input power – Cooling rated / Min–Max | 2.08 kW / 0.24–3.15 kW | | Input power – Heating rated / Min–Max | 1.91 kW / 0.14–3.00 kW | | EER / COP | 3.41 / 4.19 | | Running current – Cooling / Heating | 8.9 A / 8.3 A | | Moisture removal | 2.7 L/h | | Indoor sound pressure – Cooling high / quiet | 49 / 29 dBA | | Indoor sound pressure – Heating high / quiet | 49 / 29 dBA | | Outdoor sound pressure – Cooling / Heating | 54 / 52 dBA | | Outdoor sound power | 66 dBA | | Indoor airflow – Cooling / Heating | 325 / 325 L/s | | Maximum pipe length / pre-charge | 30 m / 15 m | | Maximum height difference | 25 m | | Cooling operating range | -10 to 46°C DB | | Heating operating range | -15 to 24°C DB | | Refrigerant charge | 1,320 g R32 |
| Seasonal performance | | Metric | Hot | Average | Cold | | Cooling star rating | 3.5 | 3.5 | 3.5 | | Heating star rating | 3.0 | 2.5 | 2.0 | | Residential TCSPF | 5.307 | 5.039 | 5.400 | | Residential HSPF | 4.779 | 4.212 | 3.525 | | Commercial TCSPF | 5.873 | 6.234 | 7.030 | | Commercial HSPF | 4.775 | 4.421 | 3.856 |
| 3. Dimensions and piping | | Item | Detail | | Indoor unit dimensions | 280 × 980 × 240 mm | | Indoor unit weight | 12.5 kg | | Outdoor unit dimensions | 716 × 820 × 315 mm | | Outdoor unit weight | 42 kg | | Piping – Liquid / Gas | 6.35 mm / 12.70 mm |
| 4. Controls and communication | | Item | Detail | | UART communication | Yes | | UART communication port | CN6 | | Included controller | AR-REW1E wireless remote controller |
| 5. What is included | | Included item | Description | | ASTG24KMTC | Indoor unit | | AOTG24KMTC | Outdoor unit | | AR-REW1E | Wireless remote controller |
| 6. Optional parts and interfaces | | Model | Description | | UTY-NXT-BOX | WiFi Control | | UTY-RHRY | Wired Remote Controller - Simple Controller Without Mode Button. Optional Communication Kit (UTY-TWRXZ2) is required for installation. | | UTY-RNRYZ3 | Wired Remote Controller - Backlit Touch Panel Wall Controller. Optional Communication Kit (UTY-TWRXZ2) is required for installation. | | UTY-RSRY | Wired Remote Controller - Simple Controller With Mode Button. Optional Communication Kit (UTY-TWRXZ2) is required for installation. | | UTY-TWRXZ2 | Communication Kit | | UTY-XCSXZ2 | External Input & Output PCB | | UTY-XWZXZ5 | External Control Wiring Kit. Optional External Input & Output PCB (UTY-XCSXZ2) is required for installation. |
| 7. Key features | | Feature | Description | | All DC | With All DC, electricity loss is decreased and power consumption reduced. | | Apple-Catechin Filter | Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples. | | Auto Restart | Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored. | | Auto Shut Louvre | The auto shut louvres close or open automatically when the unit stops or starts. | | Auto Changeover | The unit automatically switches between operating modes based on the temperature setting and room temperature. | | Automatic Air Flow Adjustment | The micro-processor automatically adjusts the air flow to follow changes in room temperature. | | Automatic Louvre | The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control. | | Auto-Off Timer | Automatically stops the units operation when a fixed time has elapsed from the start of operation. | | Blue Fin Heat Exchanger | Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger. | | Demand Response | This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation. | | Double Swing Automatic | Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions. | | Economy Mode | Limits the maximum operation current, and performs operation with the power consumption suppressed. | | Filter Sign | Select appropriate intervals for displaying the filter sign on
the indoor unit according to the estimated amount of dust in
the air of the room. | | Human Sensor | Human sensor detects movement of people within the conditioned room. | | i-PAM | i-PAM inverter technology enables high output and high efficiency performance. | | Long-Life Ion Deodorisation Filter | The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic. | | Low Noise Mode | The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise. | | On-Off Timer | ON-OFF timer can be set to operate once every 24 hours. | | Powerful Mode | Powerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable. | | Program Timer | This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON. | | Right / Left Swing Louvre | The right/left louvre automatically swings in either direction. | | Sleep Timer | The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night. | | Super Quiet Mode | The indoor units fan can operate at a low speed to produce quieter operation. | | Up/Down Swing Louvre | The up/down louvre automatically swings up and down. | | V-PAM | v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency. | | Washable Panel | Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth. | | Weekly Timer | Different ON-OFF times can be set for up to 7 days. | | 10°C Heat Operation | The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied. |
| 8. Operating manual and product links | | | Product note: Confirm current accessory compatibility, controller requirements and installation details against the latest product page and technical manuals before ordering or installation. |
| | GENERAL AIRSTAGE | ASTG24KMTC Product Reference |
|
Did you find it helpful?
Yes
No