GENERAL AIRSTAGE PRODUCT REFERENCE ASTH18KMTD Lifestyle Range | Wall Mounted Reverse Cycle Specifications, controls, included equipment, optional parts and key features | System combination Indoor: ASTH18KMTD Outdoor: AOTH18KMTD Included controller: AR-REW1E wireless remote controller Refrigerant: R32 |
| Quick navigation Quick Summary Specifications Dimensions Controls Included Optional Parts Features Operating Manual | 1. Quick summary | | Item | Detail | | Product category | Wall Mounted | | Product range | Lifestyle range | | Recommended room size | Medium room | | Operation type | Reverse cycle | | Cooling capacity | 5.00 kW rated | | Heating capacity | 6.00 kW rated | | Power supply | 230 V / 1 Ph / 50 Hz | | Refrigerant | R32 |
| 2. Technical specifications | | Specification | Value | | Cooling capacity – Rated / Min–Max | 5.00 kW / 1.0–6.5 kW | | Heating capacity – Rated / Min–Max | 6.00 kW / 1.05–8.7 kW | | Input power – Cooling rated / Min–Max | 1.16 kW / 0.24–1.93 kW | | Input power – Heating rated / Min–Max | 1.28 kW / 0.14–2.75 kW | | EER / COP | 4.31 / 4.69 | | Running current – Cooling / Heating | 5.3 A / 5.8 A | | Moisture removal | 1.3 L/h | | Indoor sound pressure – Cooling high / quiet | 46 / 29 dBA | | Indoor sound pressure – Heating high / quiet | 46 / 29 dBA | | Outdoor sound pressure – Cooling / Heating | 47 / 49 dBA | | Outdoor sound power | 59 dBA | | Indoor airflow – Cooling / Heating | 283 / 286 L/s | | Maximum pipe length / pre-charge | 30 m / 25 m | | Maximum height difference | 25 m | | Cooling operating range | -10 to 50°C DB | | Heating operating range | -15 to 24°C DB | | Refrigerant charge | 1,270 g R32 |
| Seasonal performance | | Metric | Hot | Average | Cold | | Cooling star rating | 5.0 | 4.5 | 5.0 | | Heating star rating | 3.5 | 3.0 | 2.5 | | Residential TCSPF | 6.652 | 6.3 | 6.726 | | Residential HSPF | 5.004 | 4.676 | 4.181 | | Commercial TCSPF | 7.428 | 7.934 | 9.086 | | Commercial HSPF | 4.631 | 4.393 | 4.376 |
| 3. Dimensions and piping | | Item | Detail | | Indoor unit dimensions | 280 × 980 × 240 mm | | Indoor unit weight | 12.5 kg | | Outdoor unit dimensions | 716 × 820 × 325 mm | | Outdoor unit weight | 42 kg | | Piping – Liquid / Gas | 6.35 mm / 12.70 mm |
| 4. Controls and communication | | Item | Detail | | UART communication | Yes | | UART communication port | 2 ports: CN65 and CN75 | | Included controller | AR-REW1E wireless remote controller |
| 5. What is included | | Included item | Description | | ASTH18KMTD | Indoor unit | | AOTH18KMTD | Outdoor unit | | AR-REW1E | Wireless remote controller |
| 6. Optional parts and interfaces | | Model | Description | | UTY-NXT-BOX | Wi-Fi control. | | UTY-RHRYT | Wired remote controller – simple controller without mode button. Requires UTY-TWRXZ2 communication kit. | | UTY-RNRYT5 | Wired remote controller – backlit touch-panel wall controller. Requires UTY-TWRXZ2 communication kit. | | UTY-RSRYT | Wired remote controller – simple controller with mode button. Requires UTY-TWRXZ2 communication kit. | | UTY-RVRY | KAGAMI wired remote controller. Requires UTY-TWRXZ2 communication kit. | | UTY-TWRXZ2 | Communication kit. | | UTY-XCSXZ2 | External input and output PCB. | | UTY-XWZXZ5 | External control wiring kit. Requires UTY-XCSXZ2 external input and output PCB. |
| 7. Key features | | Feature | Description | | All DC | Reduces electrical losses and power consumption. | | Apple-Catechin Filter | Captures fine dust, mould spores and microorganisms using static electricity and apple-derived polyphenol treatment. | | Auto Restart | Restarts in the previous operating mode after a temporary power interruption. | | Auto Shut Louvre | Automatically opens when operation starts and closes when the unit stops. | | Auto Changeover | Automatically switches operating mode according to set temperature and room temperature. | | Automatic Airflow Adjustment | Automatically changes airflow to follow room-temperature conditions. | | Automatic Louvre | Automatically sets louvre position to suit the operating mode, with manual adjustment available from the remote. | | Auto-Off Timer | Stops operation automatically after a selected period. | | Blue Fin Heat Exchanger | Improves outdoor heat-exchanger corrosion resistance, particularly in coastal environments. | | Demand Response | Compatible with approved air-conditioning demand-response programs. | | Double Swing Automatic | Provides automatic horizontal and vertical louvre movement. | | Right / Left Swing Louvre | Automatically swings airflow left and right. | | Economy Mode | Limits maximum operating current and suppresses power consumption. | | Filter Sign | Displays a filter reminder at selectable intervals based on expected dust loading. | | Human Sensor | Detects movement within the conditioned room. | | i-PAM | Inverter technology designed to provide high output and high-efficiency performance. | | Long-Life Ion Deodorisation Filter | Deodorises by breaking down absorbed odours using ions generated by ultra-fine ceramic particles. | | Low Noise Mode | Limits compressor and outdoor fan speed to reduce outdoor operational noise. | | On-Off Timer | Can be set to operate once every 24 hours. | | Powerful Mode | Runs the indoor fan and compressor at high output to condition the room quickly. | | Program Timer | Supports ON, OFF, ON-to-OFF and OFF-to-ON schedules. | | Sleep Timer | Gradually adjusts temperature for comfortable sleeping. | | Super Quiet Mode | Allows low indoor-fan speed for quieter operation. | | Up/Down Swing Louvre | Automatically swings the vertical airflow louvre. | | V-PAM | Inverter technology that increases compressor output while supporting high efficiency. | | Washable Panel | Allows accumulated dust to be cleaned with a damp cloth. | | Weekly Timer | Allows different ON/OFF schedules for up to seven days. | | 10°C Heat Operation | Maintains a minimum room temperature of approximately 10°C when the space is unoccupied. |
| 8. Operating manual | | | Product note: Confirm current accessory compatibility, controller requirements and installation details against the latest product page and technical manuals before ordering or installation. |