Button guideQuick startOn / OffModeTemperatureFan speedMenu mapEconomyAuto returnTemp rangeOn timerOff timerWeekly timerAuto-off timerDate / timeScreenFilter signR.C. sensorRoom tempKey lockInitial settingsZone singleZone groupDay / NightName settingCleaningError responseTroubleshooting
1. Controller button guide
| Button | Name | What it does |
|---|---|---|
Prev screen | Screen switch left | Moves to the previous screen/page where the display shows a previous-screen option. |
Next screen | Screen switch right | Moves to the next screen/page where the display shows a next-screen option. |
Menu | Menu | From Monitor, opens Menu. Press Menu again from the Menu screen to open Submenu. |
| ⊗Cancel | Cancel / Back | Cancels a change or returns to the previous screen. Hold for around 3 seconds on Monitor to lock/unlock if key lock is set. |
| ⏻ / IOn / Off | On / Off | Starts or stops operation. |
| ↵Enter | Enter | Confirms the selected item or saves the setting. |
| ▲Up ▼Down | Up / Down | Changes the selected value or moves up/down through lists. |
| ◀Left ▶Right | Left / Right | Moves across fields on the same screen, such as Mode, Set temp. and Fan. |
2. Quick start
Quick start - everyday operation
Wake the screen
Press any key if the display is asleep. If the backlight was off, the first press may only wake the screen.
↵Enter
↓
Start operation
Press On / Off once. The green power indicator lights when the unit is running.
⏻ / IOn / Off
↓
Select operation mode
Move to Mode, then choose Auto, Cool, Dry, Fan or Heat.
◀Left ▶Right ▲Up ▼Down
↓
Set temperature
Move to Set temp. and adjust the target temperature.
◀Left ▶Right ▲Up ▼Down
↓
Set fan speed
Move to Fan and choose Auto, High, Medium or Low.
◀Left ▶Right ▲Up ▼Down
↓
Need advanced settings?
Press Menu for Function/Timer. Press Menu again for Submenu.
Menu
MenuIn a zone-controlled system, operation may take around 1 minute to start while dampers prepare.
3. Basic operation flowcharts
3.1 Turn the unit On or Off
On / Off
Start from Monitor
The main screen shows Mode, Set temp. and Fan.
↓
Press On / Off
Press once to start or stop.
⏻ / IOn / Off
↓
Confirm status
Green power light ON = running. Green power light OFF = stopped.
3.2 Change operation mode
Mode selection
Highlight Mode
Use Left / Right until Mode is selected.
◀Left ▶Right
↓
Change Mode
Use Up / Down to select Auto, Cool, Dry, Fan or Heat.
▲Up ▼Down
↓
Leave on required mode
The selection applies from the Monitor screen.
Only modes available to that indoor unit will be shown. Dry mode forces fan speed to Auto.
3.3 Adjust set temperature
Set temperature
Highlight Set temp.
Use Left / Right until Set temp. is selected.
◀Left ▶Right
↓
Adjust the target temperature
Use Up / Down to increase or decrease the set temperature.
▲Up ▼Down
↓
Check range
Cool / Dry / Auto: 18 to 30°C. Heat: 16 to 30°C.
Temperature cannot be adjusted when operating in Fan mode.
3.4 Change fan speed
Fan speed
Highlight Fan
Use Left / Right until Fan is selected.
◀Left ▶Right
↓
Change fan speed
Use Up / Down to select Auto, High, Medium or Low.
▲Up ▼Down
↓
Check operating mode
In Dry mode, fan speed stays on Auto.
3.5 Menu and Submenu navigation
Menu / Submenu map
Open Menu
From Monitor, press Menu once.
Menu↓
Open Submenu
From Menu, press Menu again.
Menu↓
Move through the list
Use Up / Down to select the item.
▲Up ▼Down
↓
Open selected item
Press Enter.
↵Enter
↓
Return / cancel
Press Cancel to return one level or cancel the setting.
⊗Cancel
4. Function menu flowcharts
Economy
Economy
Open Function menu
Press Menu, select Function, then press Enter.
Menu ▲Up ▼Down ↵Enter↓
Select the item
Function menu → Economy.
▲Up ▼Down ↵Enter
↓
Adjust and save
Choose On or Off and press Enter.
◀Left ▶Right ▲Up ▼Down ↵Enter
Set temperature auto return
Set temperature auto return
Open Function menu
Press Menu, select Function, then press Enter.
Menu ▲Up ▼Down ↵Enter↓
Select the item
Function menu → Set temp. auto return.
▲Up ▼Down ↵Enter
↓
Adjust and save
Enable/disable, then set return time and return temperature.
◀Left ▶Right ▲Up ▼Down ↵Enter
Set temperature range limitation
Set temperature range limitation
Open Function menu
Press Menu, select Function, then press Enter.
Menu ▲Up ▼Down ↵Enter↓
Select the item
Function menu → Set temp. range.
▲Up ▼Down ↵Enter
↓
Adjust and save
Enable/disable, then set lower and upper limits for each mode.
◀Left ▶Right ▲Up ▼Down ↵Enter
5. Timer flowcharts
On timer
On timer
Open Timer menu
Press Menu, select Timer, then press Enter.
Menu ▲Up ▼Down ↵Enter↓
Select On timer
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust timer
Set the start delay up to 24 hours in 30-minute steps.
◀Left ▶Right ▲Up ▼Down ↵Enter
A power interruption cancels On/Off timer settings.
Off timer
Off timer
Open Timer menu
Press Menu, select Timer, then press Enter.
Menu ▲Up ▼Down ↵Enter↓
Select Off timer
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust timer
Set the stop delay up to 24 hours in 30-minute steps.
◀Left ▶Right ▲Up ▼Down ↵Enter
A power interruption cancels On/Off timer settings.
Auto-off timer
Auto-off timer
Open Timer menu
Press Menu, select Timer, then press Enter.
Menu ▲Up ▼Down ↵Enter↓
Select Auto-off timer
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust timer
Enable, set Stop in, then set Valid hour. It only counts down when operation was started by this controller.
◀Left ▶Right ▲Up ▼Down ↵Enter
A power interruption cancels On/Off timer settings.
Weekly timer
Weekly timer - simplified
Open Weekly timer
Menu → Timer → Weekly timer.
Menu ▲Up ▼Down ↵Enter↓
Select Weekly 1 or Weekly 2
Choose the schedule bank to use.
▲Up ▼Down ↵Enter
↓
Select days
Use Left / Right to move across days and Enter/Up/Down to select as required.
◀Left ▶Right ▲Up ▼Down ↵Enter
↓
Set each time pattern
For each pattern, set time, On/Off, mode and temperature as required.
◀Left ▶Right ▲Up ▼Down ↵Enter
↓
Save
Select End and press Enter.
▲Up ▼Down ↵Enter
If zone control is fitted, weekly timer On patterns may also need sensor and zone selections before they work.
6. Submenu flowcharts
Date and time
Date and time
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open Date and time
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
Set the date, time, summer time/daylight saving and display format.
◀Left ▶Right ▲Up ▼Down ↵Enter
Screen settings
Screen settings
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open Screen
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
Set automatic off time, brightness and contrast.
◀Left ▶Right ▲Up ▼Down ↵Enter
Filter sign
Filter sign
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open Filter sign
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
After cleaning the filter, reset the filter sign and choose whether the icon displays.
◀Left ▶Right ▲Up ▼Down ↵Enter
R.C. sensor control
R.C. sensor control
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open R.C. sensor control
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
Choose whether the remote controller's built-in temperature sensor is used.
◀Left ▶Right ▲Up ▼Down ↵Enter
Room temperature display
Room temperature display
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open Room temp. display
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
Choose whether the approximate room temperature is shown on Monitor.
◀Left ▶Right ▲Up ▼Down ↵Enter
Key lock
Key lock
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open Key lock select
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
Choose Child lock or Part lock. Hold Cancel for around 3 seconds on Monitor to lock/unlock.
◀Left ▶Right ▲Up ▼Down ↵Enter
Initial settings
Initial settings
Open Submenu
From Monitor, press Menu, then press Menu again.
Menu
Menu↓
Open Initial
Use Up / Down and press Enter.
▲Up ▼Down ↵Enter
↓
Adjust and save
Set language and temperature unit where available.
◀Left ▶Right ▲Up ▼Down ↵Enter
7. Zone control flowcharts
These functions only apply where the optional zone control interface is installed.
Zone (single)
Zone (single)
Open screen
From Monitor, press Next screen once.
Next screen↓
Adjust and save
Tick or untick each zone, then choose the room temperature sensor.
◀Left ▶Right ▲Up ▼Down ↵Enter
Depending on installation settings, the controller may require at least one zone to remain open.
Zone (group)
Zone (group)
Open screen
From Monitor, press Next screen twice.
Next screen↓
Adjust and save
Choose Day, Night or All.
◀Left ▶Right ▲Up ▼Down ↵Enter
Depending on installation settings, the controller may require at least one zone to remain open.
Day / Night grouping
Day / Night grouping
Open screen
Submenu → Zone user setting → Day/Night setting.
Menu
Menu ▲Up ▼Down ↵Enter↓
Adjust and save
Select the zones and room temperature sensor for Day and Night groups.
◀Left ▶Right ▲Up ▼Down ↵Enter
Depending on installation settings, the controller may require at least one zone to remain open.
Name setting
Name setting
Open screen
Submenu → Zone user setting → Name setting.
Menu
Menu ▲Up ▼Down ↵Enter↓
Adjust and save
Rename zones, groups or sensors. Maximum 12 characters.
◀Left ▶Right ▲Up ▼Down ↵Enter
Depending on installation settings, the controller may require at least one zone to remain open.
8. Cleaning and fault response
Cleaning and care
Cleaning and care
Stop operation
Turn the unit off before cleaning.
⏻ / IOn / Off
↓
Isolate if required
Disconnect power before deeper cleaning or service work.
↓
Clean safely
Do not pour water or cleaning solvent directly onto the unit. Do not use benzene, thinner, insecticide or hairspray.
↓
Keep outdoor unit clear
Remove leaves/debris around the outdoor unit.
Error response
When an error occurs
Power indicator blinks or error screen appears
An abnormal condition is present.
↓
Stop operation
Press On / Off.
⏻ / IOn / Off
↓
Record the details
Record the error code and R.C. address if shown.
↓
Escalate
Contact authorised service personnel.
9. Troubleshooting quick guide
| Issue | Likely meaning / check |
|---|---|
| Unit does not start immediately | A 3-minute compressor protection delay may be active after stopping or power restoration. |
| Weak airflow in heating | Can be normal during warm-up, thermostat-off or automatic defrost. |
| Mist or steam appears | Can be normal during cooling/dry or heating defrost. |
| Filter icon shows | Clean the filter first, then reset the filter sign. |
| Poor cooling/heating | Check filters, blocked inlet/outlet, open doors/windows, sunlight load, heat sources and set temperature. |
| Timer not working | Confirm the timer was fully programmed. A power outage cancels On/Off timer settings. |
| Auto-off timer not working | It only works when the unit was started by this controller's On/Off button. |
| Some settings cannot be changed | Controller may be key-locked, management-restricted or set as a secondary controller. |
| Zone system slow to start | Dampers may take about 1 minute before operation begins. |