| Indoor unit type | Indoor model codes | Wired Remote Controller (Touch panel) UTY-RNRYZ2 / UTY-RNRYZ1 / UTY-RNRY | Wired Remote Controller UTY-RNKYT | Simple Remote Controller UTY-RSRY / UTY-RHRY / UTY-RSKYT / UTY-RHKYT | Wireless Remote Controller UTY-LNHY | External Switch Controller UTY-TERX / UTY-TEKX | Notes |
|---|---|---|---|---|---|---|---|
| Compact Cassette | AUXB07GALH, AUXB09GALH, AUXB12GALH, AUXB14GALH, AUXB18GALH, AUXB24GALH | Yes | Yes | Yes | Yes | Yes | Fully compatible across all listed controller types. |
| Cassette | AUXD18GALH, AUXD24GALH, AUXA18GALH, AUXA24GALH, AUXA30GALH, AUXA34GALH, AUXA36GALH, AUXA45GALH, AUXA54GALH | Yes | Yes | Yes | Conditional | Yes | Wireless requires IR Receiver Unit UTY-LRHYB1. |
| Circular Flow Cassette | AUXM018GLAH, AUXM024GLAH, AUXM030GLAH, AUXK018GLAH, AUXK024GLAH, AUXK030GLAH, AUXK034GLAH, AUXK036GLAH, AUXK045GLAH, AUXK054GLAH | Yes | No | Conditional | Conditional | Conditional | Polar 3-wire controllers cannot be connected. Wireless requires UTY-LBHXD. |
| Low Static Pressure Duct / Concealed Floor | ARXB07GALH, ARXB09GALH, ARXB12GALH, ARXB14GALH, ARXB18GALH | Yes | Yes | Yes | Conditional | Yes | Wireless requires UTB-TWC. |
| Mini Duct | ARXK07GCLH, ARXK07GALH, ARXK09GCLH, ARXK09GALH, ARXK12GCLH, ARXK12GALH, ARXK14GCLH, ARXK14GALH, ARXK18GCLH, ARXK18GALH, ARXK24GCLH, ARXK24GALH | Yes | Yes | Yes | Conditional | Yes | Wireless requires UTB-TWC. |
| Slim Duct / Slim Concealed Floor | ARXD07GALH, ARXD09GALH, ARXD12GALH, ARXD14GALH, ARXD18GALH, ARXD24GALH | Yes | Yes | Yes | Conditional | Yes | Wireless requires UTB-TWC. |
| Low Static Pressure Duct | ARXB24GALH, ARXB30GALH, ARXB36GALH, ARXB45GALH | Yes | Yes | Yes | Conditional | Yes | Wireless requires UTB-TWC. |
| Medium Static Pressure Duct | ARXA24GALH, ARXA30GALH, ARXA36GALH, ARXA45GALH, ARXA24GBLH, ARXA30GBLH, ARXA36GBLH, ARXA45GBLH | Yes | Yes | Yes | Conditional | Yes | Wireless requires UTB-TWC. |
| High Static Pressure Duct | ARXC36GATH, ARXC45GATH, ARXC60GATH, ARXC72GATH, ARXC90GATH, ARXC96GATH, ARXC36GBTH | Yes | Yes | Yes | Conditional | Yes | Wireless requires UTB-TWC. |
| Compact Floor | AGYA007GCAH, AGYA009GCAH, AGYA012GCAH, AGYA014GCAH | Yes | No | Conditional | Yes | Conditional | Polar 3-wire controllers cannot be connected. |
| Compact Floor (EEV external) | AGYE007GCAH, AGYE009GCAH, AGYE012GCAH, AGYE014GCAH | Yes | No | Conditional | Yes | Conditional | Same controller logic as Compact Floor. |
| Floor / Ceiling | ABYA12GATH, ABYA14GATH, ABYA18GATH, ABYA24GATH | Yes | Yes | Yes | Yes | Yes | Fully compatible across all listed controller types. |
| Ceiling | ABYA30GATH, ABYA36GATH, ABYA45GATH, ABYA54GATH | Yes | Yes | Yes | Yes | Yes | Fully compatible across all listed controller types. |
| Wall Mounted | ASYA007GTAH, ASYA009GTAH, ASYA07GACH, ASYA09GACH, ASYA12GACH, ASYA14GACH, ASYA18GACH, ASYA24GACH, ASYA30GACH, ASYA18GBCH, ASYA24GBCH | Yes | Conditional | Conditional | Yes | Conditional | Wired remote is not connectable with indoor unit AS*****GTAH. |
| Wall Mounted (EEV external) | ASYE007GTAH, ASYE009GTAH, ASYE07GACH, ASYE09GACH, ASYE12GACH, ASYE14GACH | Yes | Conditional | Conditional | Yes | Conditional | Same wall-mounted controller restrictions apply. |