1. Quick answer

Indoor unitARTG18LLTA
Outdoor unitAOTG18LACC
Power supplySingle phase, 240 V, 50 Hz
Rated cooling capacity5.20 kW
Rated heating capacity6.00 kW
EER / COP3.59 / 3.85 kW/kW
RefrigerantR410A, factory charge 1,650 g
Maximum pipe length / height30 m / 20 m

2. Model mapping and electrical specifications

ItemSpecification
Matched indoor unitARTG18LLTA
Matched outdoor unitAOTG18LACC
Power supply240 V AC, single phase, 50 Hz
Available voltage range198-264 V
Maximum operating currentCooling 9.6 A; heating 13.1 A
Starting current7.0 A
Technical-manual sample circuit breaker25 A
Electrical wiring, cable sizing and circuit protection must comply with the applicable local standards and installation requirements. The values above are technical-manual reference data, not a substitute for site-specific electrical design.

3. Rated performance

SpecificationCoolingHeating
Rated capacity5.20 kW6.00 kW
Capacity range0.90-5.90 kW0.90-7.50 kW
Rated input power1.45 kW1.56 kW
Maximum input power1.61 kW2.31 kW
Rated operating current6.1 A6.6 A
EfficiencyEER 3.59 kW/kWCOP 3.85 kW/kW
Moisture removal2.0 L/h-

4. Fan, airflow and sound levels

Indoor airflow - ARTG18LLTA

Fan speedm³/hL/sCFM
High940261553
Medium880244518
Low820227483
Quiet750208441
Sound pressure levelCoolingHeating
Indoor - High32 dB(A)32 dB(A)
Indoor - Quiet27 dB(A)27 dB(A)
Outdoor55 dB(A)56 dB(A)
Outdoor fan dataCoolingHeating
Airflow2,460 m³/h2,460 m³/h
Fan speed1,100 rpm1,100 rpm
Sound values are measured in the manufacturer's anechoic chamber. Actual site readings may be higher because of the installation environment, ductwork, reflective surfaces and background noise.

5. Dimensions and weight

UnitNet dimensions H × W × DShipping dimensions H × W × DWeight
ARTG18LLTA indoor198 × 900 × 620 mm276 × 1,168 × 772 mm23 kg net / 27 kg gross
AOTG18LACC outdoor620 × 790 × 290 mm713 × 945 × 395 mm41 kg net / 44 kg gross

6. Compressor, refrigerant and piping

ItemSpecification
CompressorTwin rotary × 1, motor output 1,100 W
RefrigerantR410A
Factory charge1,650 g, covering total pipe length up to 15 m
Additional charge20 g/m over 15 m: 100 g at 20 m, 200 g at 25 m and 300 g at 30 m
Refrigerant oilPOE (RB68)
Liquid pipeØ6.35 mm (1/4 in.) flare
Gas pipeØ12.70 mm (1/2 in.) flare
Maximum pipe length30 m
Maximum height difference20 m

7. Operating range

ConditionRange
Outdoor cooling-10°C to 46°C
Outdoor heating-15°C to 24°C
Indoor cooling18°C to 32°C, 80% RH or less
Indoor heating16°C to 30°C

8. Direct answers to common questions

QWhat is the cooling capacity?
5.20 kW rated.
QWhat is the heating capacity?
6.00 kW rated.
QWhat are the EER and COP?
EER 3.59 and COP 3.85 kW/kW.
QDoes the system support a 30 m pipe run?
Yes. The maximum total pipe length is 30 m, with 20 g/m additional R410A required above 15 m.
QWhat is the maximum height difference?
20 m.
QWhat is the indoor airflow range?
750-940 m³/h across Quiet to High fan speed.
QWhat are the indoor and outdoor sound levels?
Indoor: 27 dB(A) Quiet and 32 dB(A) High. Outdoor: 55 dB(A) cooling and 56 dB(A) heating.
Important: Rated values are based on the manufacturer's standard test conditions, including a 7.5 m pipe length, zero height difference and 25 Pa standard static pressure. Actual performance varies with indoor and outdoor temperatures, airflow, external static pressure, pipe length and installation quality.
Source: Fujitsu General Design & Technical Manual DTR_AR057E_02 / DTR_AO124E_02, dated 30 September 2014, covering ARTG09LLLB / ARTG12LLLB / ARTG18LLTA and AOTG18LACC / AOTG24LATC.