1. Quick answer

Indoor unitARTG09LLLB
Outdoor unitAOTG09LBCA or AOTG09LBCB
Power supplySingle phase, 240 V, 50 Hz
Rated cooling capacity2.60 kW
Rated heating capacity3.50 kW
EER / COP3.94 / 4.22 kW/kW
RefrigerantR410A, factory charge 1,200 g
Maximum pipe length / height20 m / 15 m

2. Model mapping and electrical specifications

ItemSpecification
Matched indoor unitARTG09LLLB
Matched outdoor unitsAOTG09LBCA and AOTG09LBCB
Power supply240 V AC, single phase, 50 Hz
Available voltage range198-264 V
Maximum operating currentCooling 9.3 A; heating 10.8 A
Starting current3.9 A
Wiring and circuit protection must comply with applicable local electrical requirements. The technical manual lists different sample breaker and cable selections for the LBCA and LBCB outdoor variants.

3. Rated performance

SpecificationCoolingHeating
Rated capacity2.60 kW3.50 kW
Capacity range0.90-3.75 kW0.90-5.51 kW
Rated input power0.66 kW0.83 kW
Maximum input power1.46 kW1.88 kW
Rated operating current3.1 A3.9 A
EfficiencyEER 3.94 kW/kWCOP 4.22 kW/kW
Moisture removal0.7 L/h-

4. Fan, airflow and sound levels

Indoor airflow - ARTG09LLLB

Fan speedm³/hL/sCFM
High600167353
Medium550153324
Low500139294
Quiet450125265
Sound pressure levelCoolingHeating
Indoor - High28 dB(A)28 dB(A)
Indoor - Quiet25 dB(A)24 dB(A)
Outdoor41 dB(A)46 dB(A)
Sound values are measured in the manufacturer's anechoic chamber. Actual site readings may be higher because of the installation environment, ductwork, reflective surfaces and background noise.

5. Dimensions and weight

UnitNet dimensions H × W × DShipping dimensions H × W × DWeight
ARTG09LLLB indoor198 × 700 × 620 mm274 × 945 × 772 mm18 kg net / 22 kg gross
AOTG09LBCA / LBCB outdoor620 × 790 × 290 mm713 × 945 × 395 mm39 kg net / 42 kg gross

6. Compressor, refrigerant and piping

ItemSpecification
CompressorDC twin rotary × 1, motor output 850 W
RefrigerantR410A
Factory charge1,200 g, covering total pipe length up to 15 m
Additional charge20 g/m over 15 m; 100 g additional at the 20 m maximum
Refrigerant oilFREOL α68SZ, 350 cm³
Liquid pipeØ6.35 mm (1/4 in.) flare
Gas pipeØ9.52 mm (3/8 in.) flare
Maximum pipe length20 m
Maximum height difference15 m

7. Operating range

ConditionRange
Outdoor cooling-10°C to 46°C
Outdoor heating-15°C to 24°C
Indoor cooling18°C to 32°C, 80% RH or less
Indoor heating16°C to 30°C

8. Direct answers to common questions

QWhat is the cooling capacity?
2.60 kW rated.
QWhat is the heating capacity?
3.50 kW rated.
QWhat are the EER and COP?
EER 3.94 and COP 4.22 kW/kW.
QDoes the system support a 20 m pipe run?
Yes. The maximum total pipe length is 20 m, with 20 g/m additional R410A required above 15 m.
QAre AOTG09LBCA and AOTG09LBCB both compatible?
Yes. Both are listed as matched outdoor units for ARTG09LLLB.
QWhat is the indoor airflow range?
450-600 m³/h across Quiet to High fan speed.
Important: Rated values are based on the manufacturer's standard test conditions, including a 7.5 m pipe length, zero height difference and 60 Pa standard static pressure. Actual performance varies with indoor and outdoor temperatures, airflow, external static pressure, pipe length and installation quality.
Source: Fujitsu General Design & Technical Manual DR_AR007EF_05, dated 29 May 2020, covering ARTG09LLLB / ARTG12LLLB / ARTG18LLLA and AOTG09LBCA / AOTG12LBCA / AOTG18LACC / AOTG09LBCB / AOTG12LBCB.