General Assist Technical Reference

ARTG18LLLA & AOTG18LACC

Matched ducted system technical specifications
Indoor unit: ARTG18LLLA  |  Outdoor unit: AOTG18LACC  |  Refrigerant: R410A
This article provides the principal performance, electrical, dimensional, airflow, noise and refrigerant specifications for the ARTG18LLLA indoor unit and its matched AOTG18LACC outdoor unit.

1. Quick answer

Indoor unit modelARTG18LLLA
Outdoor unit modelAOTG18LACC
Matched systemYes
Power supplySingle phase, 240 V, 50 Hz
Cooling capacity5.20 kW
Heating capacity6.00 kW
EER / COP3.59 / 3.85 kW/kW
RefrigerantR410A
Maximum pipe length / height30 m / 20 m

2. Electrical and performance specifications

Electrical supply

ItemSpecification
Supply240 V, single phase, 50 Hz
Available voltage range198–264 V
Maximum operating current13.1 A
Starting current7.0 A
Manual circuit-breaker reference25 A — confirm all wiring and protection against current local requirements
Cooling
Rated capacity: 5.20 kW
Capacity range: 0.90–5.90 kW
Rated input: 1.45 kW
Maximum input: 1.61 kW
EER: 3.59 kW/kW
Rated current: 6.1 A
Maximum current: 9.6 A
Moisture removal: 2.0 L/h
Heating
Rated capacity: 6.00 kW
Capacity range: 0.90–7.50 kW
Rated input: 1.56 kW
Maximum input: 2.31 kW
COP: 3.85 kW/kW
Rated current: 6.6 A
Maximum current: 13.1 A

3. Compressor, refrigerant and piping

ItemSpecification
CompressorDC twin rotary × 1
Compressor motor output1,100 W
RefrigerantR410A
Factory charge1,650 g for pipe length up to 15 m
Additional charge20 g per metre over 15 m
Maximum pipe length30 m
Maximum height difference20 m
Liquid / gas pipeØ6.35 mm (1/4 in.) / Ø12.70 mm (1/2 in.), flare connection
Refrigerant oilPOE (RB68), 600 cm³
Refrigerant charging: The factory charge covers up to 15 m total pipe length. Add 100 g at 20 m, 200 g at 25 m or 300 g at the maximum 30 m pipe length.

4. Fan, airflow and sound levels

Fan settingIndoor airflowEquivalent
Quiet750 m³/h208 L/s / 441 CFM
Low820 m³/h228 L/s / 483 CFM
Medium880 m³/h244 L/s / 518 CFM
High940 m³/h261 L/s / 553 CFM
Sound / outdoor airflowCoolingHeating
Indoor sound pressure27 dB(A) quiet / 32 dB(A) high27 dB(A) quiet / 32 dB(A) high
Outdoor sound pressure55 dB(A)56 dB(A)
Outdoor airflow2,460 m³/h2,460 m³/h
Specified sound-pressure levels are laboratory values measured in an anechoic chamber. Actual installed sound levels may be higher due to the surrounding environment, ductwork and mounting conditions.

5. Dimensions and weights

UnitNet dimensions (H × W × D)Shipping dimensionsWeight
ARTG18LLLA indoor198 × 900 × 620 mm276 × 1168 × 772 mm23 kg net / 27 kg gross
AOTG18LACC outdoor620 × 790 × 290 mm713 × 945 × 395 mm41 kg net / 44 kg gross

6. Operating range

ConditionRange
Outdoor cooling-10°C to 46°C
Outdoor heating-15°C to 24°C
Indoor cooling18°C to 32°C, 80% RH or less
Indoor heating16°C to 30°C

7. Direct answers to common questions

What is the cooling capacity?
5.20 kW rated.
What is the heating capacity?
6.00 kW rated.
What are the EER and COP?
EER is 3.59 kW/kW and COP is 3.85 kW/kW.
Does this system support a 30 m pipe run?
Yes. The maximum total pipe length is 30 m, subject to the maximum 20 m height difference and correct additional refrigerant charge.
How much additional refrigerant is required?
20 g per metre over the factory pre-charge length of 15 m.
What is the indoor airflow range?
750–940 m³/h across quiet to high fan settings.
Are the indoor and outdoor models a matched pair?
Yes. ARTG18LLLA is matched with AOTG18LACC.
Source: Fujitsu General Design & Technical Manual DR_AR007EF_05, dated 29 May 2020. Specifications and designs may change without notice. Confirm current installation instructions and local electrical requirements before installation or service work.