Product Information – ARTH30KHTA-HP (SET-ARTH30KHTA-HP)
Print
Modified on: Wed, 15 Jul, 2026 at 3:07 PM
GENERAL AIRSTAGE PRODUCT REFERENCE ARTH30KHTA-HP SET-ARTH30KHTA-HP | R32 High Static Single Phase (HP) Specifications, dimensions, airflow, controls, accessories and key product features | System combination Indoor: ARTH30KHTA Outdoor: AOTH30KCTA Included wired controller: UTY-RNRT Refrigerant: R32 |
| Quick navigation Quick Summary Specifications Dimensions Duct Connections Controls Included Optional Parts Features | 1. Quick summary | | Item | Detail | | Product name | ARTH30KHTA-HP | | Product category | R32 High Static Single Phase (HP) | | Operation type | Reverse cycle | | Cooling capacity | 8.50 kW rated | | Heating capacity | 10.00 kW rated | | Static pressure range | 60–210 Pa | | Cooling operating range | -10 to 50°C DB | | Heating operating range | -15 to 24°C DB |
| 2. Technical specifications | | Specification | Value | | Power supply | 230 V / 1 Ph / 50 Hz | | Cooling capacity - Rated / Min–Max | 8.50 kW / 4.1–11.0 kW | | Heating capacity - Rated / Min–Max | 10.00 kW / 4.2–12.0 kW | | Input power - Cooling rated / max | 2.18 kW / 3.36 kW | | Input power - Heating rated / max | 2.20 kW / 3.12 kW | | EER / COP | 3.90 / 4.55 | | Running current - Cooling / Heating | 9.6 A / 9.7 A | | Moisture removal | 0.1 L/h | | Indoor sound pressure - High / Quiet | 41 / 36 dBA | | Outdoor sound pressure - Cooling / Heating | 51 / 53 dBA | | Outdoor sound power | 69 dBA | | Indoor air circulation - High fan | 695 L/s cooling and heating | | Refrigerant charge | 2,100 g R32 | | Maximum pipe length / pre-charge | 75 m / 30 m | | Maximum height difference | 30 m | | Piping - Liquid / Gas | 9.52 mm / 15.88 mm |
| Seasonal performance | | Metric | Hot | Average | Cold | | Cooling star rating | 3 | 3 | 3 | | Heating star rating | 3 | 3 | 2 | | Residential TCSPF | 4.833 | 4.593 | 4.727 | | Residential HSPF | 4.856 | 4.509 | 3.994 | | Commercial TCSPF | 5.108 | 5.148 | 5.458 | | Commercial HSPF | 4.843 | 4.624 | 4.201 |
| 3. Dimensions and weights | | Unit | Dimensions H × W × D | Weight | | Indoor | 400 × 1,050 × 500 mm | 39 kg | | Outdoor | 998 × 940 × 320 mm | 64 kg |
| 4. Duct connection dimensions | | Connection | Height × Width | | Return air | 325 × 865 mm | | Supply air | 295 × 850 mm |
| | Installation note: Dimensions above are duct connection openings, not overall cabinet dimensions. Confirm the physical unit before fabricating transitions, plenums or flexible connections. |
| 5. Controls and communication | | Item | Detail | | UART communication | Yes | | UART ports | 2 ports: CN65 and CN75 | | Included controller | UTY-RNRT backlit touch-panel wired controller |
| 6. What is included | | Included item | Description | | ARTH30KHTA-HP | Indoor unit | | AOTH30KCTA | Outdoor unit | | UTY-RNRT | Backlit touch-panel wired remote controller |
| 7. Optional parts and interfaces | | Model | Description | | UTY-ANY2 | Wi-Fi control – anywAiR Technology ducted controller | | UTY-CDRXZC | R32 zone-control interface module, 8 zones, 24 V | | UTY-CDRXZD | R32 zone-control interface module, 8 zones, 240 V | | UTY-LBTYM | Wireless remote controller and infrared receiver kit | | UTY-NXT-BOX | Wi-Fi control | | UTY-NXT-CAB | Required cable when connecting UTY-NXT-BOX to non-Lifestyle indoor units; confirm compatibility | | UTY-RHRYT | Simple wired controller without mode button | | UTY-RNRYT5 | Backlit touch-panel wired controller | | UTY-RSNYN | Simple wired controller with mode button | | UTY-RSRYT | Simple wired controller with mode button | | UTY-RVNYN | Backlit wired controller | | UTY-RVRY | KAGAMI wired remote controller | | UTY-VTGX | Network converter | | UTD-LF60KA | Accessory listed for this product | | UTY-TERX | External switch controller adaptor | | UTY-VKSX | Single-unit KNX interface | | UTY-VMSX | Single-unit Modbus converter | | UTY-VTGXV | Network converter for single split, supporting two remote controllers | | UTY-XCSX | External input/output PCB | | UTY-XSZXT | Remote sensor unit | | UTY-XWZXZ3 | External connect kit | | UTY-XWZXZG | External connection wire | | UTZ-GXEA | External input/output PCB box |
| 8. Key features | | Feature | Description | | Range overview | High Static Single Phase R32 High Performance range available from 8.5 kW to 16.0 kW, with cooling operation up to 50°C, demand-response compatibility and zone-system capability. | | Zone control | Allows selected areas to be conditioned independently through a compatible zoning system. | | Auto restart | Restarts in the previous operating mode after temporary power interruption. | | Auto changeover | Automatically selects heating or cooling according to setpoint and room temperature. | | Blue Fin heat exchanger | Improves outdoor heat-exchanger corrosion resistance, particularly in coastal environments. | | Connectable distributing duct | Supports field-supplied branch ducts for airflow distribution. | | Connectable fresh-air duct | Allows introduction of outdoor air into the occupied space. | | Demand response | Compatible with approved air-conditioning demand-response programs. | | Economy mode | Limits maximum current and reduces power consumption. | | Filter sign | Allows a filter reminder interval to be selected according to expected dust loading. | | On/Off timer | Provides a once-per-24-hour start or stop timer. | | Program timer | Supports ON, OFF, ON-to-OFF and OFF-to-ON schedules. | | Weekly timer | Allows different schedules for up to seven days. | | Automatic fan speed adjustment | Automatically changes airflow to suit room-temperature conditions. | | 50°C cooling operation | Guaranteed cooling operation up to 50°C outdoor dry-bulb temperature. | | Demo mode | Allows the indoor unit to run independently for displays and showrooms. | | Automatic static-pressure adjustment | Automatically determines the optimum static-pressure setting during commissioning. | | Long piping capability – 75 m | Supports a maximum refrigerant pipe length of 75 m, with a factory pre-charge allowance of 30 m. |
| | Product note: Confirm current accessory compatibility, controller combinations, seasonal-performance data and installation requirements against the latest product literature and technical manuals before specification or installation. |
| | GENERAL AIRSTAGE | ARTH30KHTA-HP Product Reference |
|
Did you find it helpful?
Yes
No
Send feedback Sorry we couldn't be helpful. Help us improve this article with your feedback.