GENERAL AIRSTAGE PRODUCT REFERENCE
ARTH36KHTA
SET-ARTH36KHTA | R32 High Static Single Phase
Specifications, dimensions, airflow, controls, accessories and key product features
System combination
Indoor: ARTH36KHTA
Outdoor: AOTH36KBTA
Included wired controller: UTY-RNRT
Refrigerant: R32
Quick navigation
Quick Summary Specifications Dimensions Duct Connections Controls Included Optional Parts Features
1. Quick summary
ItemDetail
Product nameARTH36KHTA
Product categoryR32 High Static Single Phase
Operation typeReverse cycle
Cooling capacity10.00 kW rated
Heating capacity11.20 kW rated
Static pressure range60–210 Pa
Cooling operating range-10 to 50°C DB
Heating operating range-15 to 24°C DB
2. Technical specifications
SpecificationValue
Power supply230 V / 1 Ph / 50 Hz
Cooling capacity - Rated / Min–Max10.00 kW / 2.8–11.4 kW
Heating capacity - Rated / Min–Max11.20 kW / 2.7–14.0 kW
Input power - Cooling rated / max3.08 kW / 4.01 kW
Input power - Heating rated / max2.80 kW / 4.21 kW
EER / COP3.25 / 4.00
Running current - Cooling / Heating13.6 A / 12.3 A
Moisture removal1.4 L/h
Indoor sound pressure - High / Quiet41 / 36 dBA
Outdoor sound pressure - Cooling / Heating53 / 53 dBA
Outdoor sound power70 dBA
Indoor air circulation - High fan695 L/s cooling and heating
Refrigerant charge1,900 g R32
Maximum pipe length / pre-charge50 m / 30 m
Maximum height difference30 m
Piping - Liquid / Gas9.52 mm / 15.88 mm
Seasonal performance
MetricHotAverageCold
Cooling star rating32.53
Heating star rating32.51.5
Residential TCSPF4.6424.4264.675
Residential HSPF4.724.0733.429
Commercial TCSPF4.9725.1445.544
Commercial HSPF4.724.343.67
3. Dimensions and weights
UnitDimensions H × W × DWeight
Indoor400 × 1,050 × 500 mm39 kg
Outdoor788 × 940 × 320 mm52 kg
4. Duct connection dimensions
ConnectionHeight × Width
Return air325 × 865 mm
Supply air295 × 850 mm
Installation note: Dimensions above are duct connection openings, not overall cabinet dimensions. Confirm the physical unit before fabricating transitions, plenums or flexible connections.
5. Controls and communication
ItemDetail
UART communicationYes
UART ports2 ports: CN65 and CN75
Included controllerUTY-RNRT backlit touch-panel wired controller
6. What is included
Included itemDescription
ARTH36KHTAIndoor unit
AOTH36KBTAOutdoor unit
UTY-RNRTBacklit touch-panel wired remote controller
7. Optional parts and interfaces
ModelDescription
UTY-ANY2Wi-Fi control – anywAiR Technology ducted controller
UTY-CDRXZCR32 zone-control interface module, 8 zones, 24 V
UTY-CDRXZDR32 zone-control interface module, 8 zones, 240 V
UTY-LBTYMWireless remote controller and infrared receiver kit
UTY-NXT-BOXWi-Fi control
UTY-NXT-CABRequired cable when connecting UTY-NXT-BOX to non-Lifestyle indoor units; confirm compatibility
UTY-RHRYTSimple wired controller without mode button
UTY-RNRYT5Backlit touch-panel wired controller
UTY-RSNYNSimple wired controller with mode button
UTY-RSRYTSimple wired controller with mode button
UTY-RVNYNBacklit wired controller
UTY-RVRYKAGAMI wired remote controller
UTY-VTGXNetwork converter
UTD-LF60KAAccessory listed for this product
UTY-TERXExternal switch controller adaptor
UTY-VKSXSingle-unit KNX interface
UTY-VMSXSingle-unit Modbus converter
UTY-VTGXVNetwork converter for single split, supporting two remote controllers
UTY-XCSXExternal input/output PCB
UTY-XSZXTRemote sensor unit
UTY-XWZXZ3External connect kit
UTY-XWZXZGExternal connection wire
UTZ-GXEAExternal input/output PCB box
8. Key features
FeatureDescription
Range overviewHigh Static Single Phase R32 range available from 7.1 kW to 15.5 kW, with cooling operation up to 50°C, demand-response compatibility and zone-system capability.
Zone controlAllows selected areas to be conditioned independently through a compatible zoning system.
Auto restartRestarts in the previous operating mode after temporary power interruption.
Auto changeoverAutomatically selects heating or cooling according to setpoint and room temperature.
Blue Fin heat exchangerImproves outdoor heat-exchanger corrosion resistance, particularly in coastal environments.
Connectable distributing ductSupports field-supplied branch ducts for airflow distribution.
Connectable fresh-air ductAllows introduction of outdoor air into the occupied space.
Demand responseCompatible with approved air-conditioning demand-response programs.
Economy modeLimits maximum current and reduces power consumption.
Filter signAllows a filter reminder interval to be selected according to expected dust loading.
On/Off timerProvides a once-per-24-hour start or stop timer.
Program timerSupports ON, OFF, ON-to-OFF and OFF-to-ON schedules.
Weekly timerAllows different schedules for up to seven days.
Automatic fan speed adjustmentAutomatically changes airflow to suit room-temperature conditions.
50°C cooling operationGuaranteed cooling operation up to 50°C outdoor dry-bulb temperature.
Demo modeAllows the indoor unit to run independently for displays and showrooms.
Automatic static-pressure adjustmentAutomatically determines the optimum static-pressure setting during commissioning.
Product note: Confirm current accessory compatibility, controller combinations, seasonal-performance data and installation requirements against the latest product literature and technical manuals before specification or installation.
GENERAL AIRSTAGE | ARTH36KHTA Product Reference