Product Information – ARTH24KHTA (SET-ARTH24KHTA)
Print
Modified on: Wed, 15 Jul, 2026 at 2:33 PM
GENERAL AIRSTAGE PRODUCT REFERENCE ARTH24KHTA SET-ARTH24KHTA | R32 High Static Single Phase Specifications, dimensions, airflow, controls, accessories and key product features | System combination Indoor: ARTH24KHTA Outdoor: AOTH24KBTA Included wired controller: UTY-RNRT Refrigerant: R32 |
| Quick navigation Quick Summary Specifications Dimensions Duct Connections Controls Included Optional Parts Features | 1. Quick summary | | Item | Detail | | Product name | ARTH24KHTA | | Product category | R32 High Static Single Phase | | Operation type | Reverse cycle | | Cooling capacity | 7.10 kW rated | | Heating capacity | 8.00 kW rated | | Static pressure range | 60–210 Pa | | Cooling operating range | -10 to 50°C DB | | Heating operating range | -15 to 24°C DB |
| 2. Technical specifications | | Specification | Value | | Power supply | 230 V / 1 Ph / 50 Hz | | Cooling capacity - Rated / Min–Max | 7.10 kW / 1.8–8.1 kW | | Heating capacity - Rated / Min–Max | 8.00 kW / 2.0–9.1 kW | | Input power - Cooling rated / max | 2.14 kW / 2.53 kW | | Input power - Heating rated / max | 2.05 kW / 2.45 kW | | EER / COP | 3.32 / 3.90 | | Running current - Cooling / Heating | 9.4 A / 9.0 A | | Moisture removal | 0.5 L/h | | Indoor sound pressure - High / Quiet | 34 / 27 dBA | | Outdoor sound pressure - Cooling / Heating | 48 / 50 dBA | | Outdoor sound power | 68 dBA | | Indoor air circulation - High fan | 500 L/s cooling and heating | | Refrigerant charge | 1,250 g R32 | | Maximum pipe length / pre-charge | 30 m / 20 m | | Maximum height difference | 25 m | | Piping - Liquid / Gas | 6.35 mm / 12.70 mm |
| Seasonal performance | | Metric | Hot | Average | Cold | | Cooling star rating | 3 | 3 | 3 | | Heating star rating | 3 | 2.5 | 1.5 | | Residential TCSF | 4.912 | 4.611 | 4.875 | | Residential HSPF | 4.825 | 4.11 | 3.444 | | Commercial TCSF | 5.299 | 5.489 | 5.931 | | Commercial HSPF | 4.831 | 4.41 | 3.707 |
| 3. Dimensions and weights | | Unit | Dimensions H × W × D | Weight | | Indoor | 400 × 1,050 × 500 mm | 38 kg | | Outdoor | 716 × 820 × 315 mm | 42 kg |
| 4. Duct connection dimensions | | Connection | Height × Width | | Return air | 325 × 865 mm | | Supply air | 295 × 850 mm |
| | Installation note: Dimensions above are duct connection openings, not overall cabinet dimensions. Confirm the physical unit before fabricating transitions, plenums or flexible connections. |
| 5. Controls and communication | | Item | Detail | | UART communication | Yes | | UART ports | 2 ports: CN65 and CN75 | | Included controller | UTY-RNRT backlit touch-panel wired controller |
| 6. What is included | | Included item | Description | | ARTH24KHTA | Indoor unit | | AOTH24KBTA | Outdoor unit | | UTY-RNRT | Backlit touch-panel wired remote controller |
| 7. Optional parts and interfaces | | Model | Description | | UTY-ANY2 | Wi-Fi control – anywAiR Technology ducted controller | | UTY-CDRXZC | R32 zone-control interface module, 8 zones, 24 V | | UTY-CDRXZD | R32 zone-control interface module, 8 zones, 240 V | | UTY-LBTYM | Wireless remote controller and infrared receiver kit | | UTY-NXT-BOX | Wi-Fi control | | UTY-NXT-CAB | Required cable when connecting UTY-NXT-BOX to non-Lifestyle indoor units; confirm compatibility | | UTY-RHRYT | Simple wired controller without mode button | | UTY-RNRYT5 | Backlit touch-panel wired controller | | UTY-RSNYN | Simple wired controller with mode button | | UTY-RSRYT | Simple wired controller with mode button | | UTY-RVNYN | Backlit wired controller | | UTY-RVRY | KAGAMI wired remote controller | | UTY-VTGX | Network converter | | UTD-LF60KA | Accessory listed for this product | | UTY-TERX | External switch controller adaptor | | UTY-VKSX | Single-unit KNX interface | | UTY-VMSX | Single-unit Modbus converter | | UTY-VTGXV | Network converter for single split, supporting two remote controllers | | UTY-XCSX | External input/output PCB | | UTY-XSZXT | Remote sensor unit | | UTY-XWZXZG | External connection wire | | UTZ-GXEA | External input/output PCB box |
| 8. Key features | | Feature | Description | | Range overview | High Static Single Phase R32 ducted range with cooling operation up to 50°C, demand-response compatibility and zone-system capability. | | Zone control | Allows selected areas to be conditioned independently through a compatible zoning system. | | Auto restart | Restarts in the previous operating mode after temporary power interruption. | | Auto changeover | Automatically selects heating or cooling according to setpoint and room temperature. | | Blue Fin heat exchanger | Improves outdoor heat-exchanger corrosion resistance, particularly in coastal environments. | | Connectable distributing duct | Supports field-supplied branch ducts for airflow distribution. | | Connectable fresh-air duct | Allows introduction of outdoor air into the occupied space. | | Demand response | Compatible with approved air-conditioning demand-response programs. | | Economy mode | Limits maximum current and reduces power consumption. | | Filter sign | Allows a filter reminder interval to be selected according to expected dust loading. | | On/Off timer | Provides a once-per-24-hour start or stop timer. | | Program timer | Supports ON, OFF, ON-to-OFF and OFF-to-ON schedules. | | Weekly timer | Allows different schedules for up to seven days. | | Automatic fan speed adjustment | Automatically changes airflow to suit room-temperature conditions. | | 50°C cooling operation | Guaranteed cooling operation up to 50°C outdoor dry-bulb temperature. | | Demo mode | Allows the indoor unit to run independently for displays and showrooms. | | Automatic static-pressure adjustment | Automatically determines the optimum static-pressure setting during commissioning. |
| | Product note: Confirm current accessory compatibility, controller combinations, seasonal-performance data and installation requirements against the latest product literature and technical manuals before specification or installation. |
| | GENERAL AIRSTAGE | ARTH24KHTA Product Reference |
|
Did you find it helpful?
Yes
No
Send feedback Sorry we couldn't be helpful. Help us improve this article with your feedback.