How to Check the Refrigerant Level
1. Refrigerant does not get used up
Unlike fuel, refrigerant circulates continuously through the indoor unit, outdoor unit and connecting pipework. Under normal conditions, the quantity of refrigerant remains unchanged for the life of the system.
2. How a technician checks the refrigerant charge
Step 1 - Assess system operation
The technician may initially check operating temperatures, pressures, airflow, electrical readings and system fault history. These checks can indicate that further refrigerant investigation is required, but they do not always confirm the exact quantity of refrigerant in the system.
Step 2 - Recover and weigh the refrigerant
The most reliable method of confirming the refrigerant quantity is to recover the complete charge using approved recovery equipment and weigh the amount removed.
The recovered quantity is then compared with the factory charge shown on the outdoor unit nameplate, together with any additional charge required for the installed pipe length.
Step 3 - Leak-test the system
If the recovered amount is below the required charge, the technician should inspect and test the refrigeration circuit, including:
- Indoor and outdoor unit coils and refrigerant components.
- Connecting pipework and insulation.
- Flare joints, brazed joints and service valves.
- Valve caps, service-port cores and accessible fittings.
- Areas showing oil residue, corrosion or physical damage.
Step 4 - Repair and evacuate
Once the leak has been found, the affected component or joint must be repaired. The refrigeration circuit is then evacuated with a vacuum pump to remove air and moisture before recharging.
Step 5 - Recharge by weight
The technician weighs in the specified refrigerant charge. The correct charge must account for the factory specification and, where applicable, the installed refrigerant pipe length.
| Stage | Purpose |
|---|---|
| Operational assessment | Checks whether system performance suggests a refrigeration, airflow, control or electrical issue. |
| Recover and weigh | Confirms the actual amount of refrigerant removed from the system. |
| Leak testing | Identifies why refrigerant was lost. |
| Evacuation | Removes air and moisture from the sealed circuit. |
| Recharge by weight | Restores the precise specified refrigerant quantity. |
3. Possible signs of low refrigerant
Low refrigerant can contribute to the following symptoms:
- Reduced cooling or heating performance.
- Long operating periods without reaching the set temperature.
- Ice forming on refrigerant pipework or the indoor coil.
- Refrigeration-related fault codes or abnormal system pressures.
- Oil staining around joints, valves or coils.
- Unusual compressor operation or increased energy use.
4. Warranty considerations
Fujitsu General warranty applies to defects arising from the manufacture of the product, subject to the applicable warranty terms and conditions.
Refrigerant loss caused by installation workmanship or external factors may not be covered. Examples can include:
- Incorrectly made or tightened flare connections.
- Leaking field-installed pipework or brazed joints.
- Damage caused during installation, building works or later service activity.
- Corrosion, impact damage or environmental causes.
- Incorrect additional refrigerant charge for the installed pipe length.
5. Summary
- Air conditioners do not normally consume refrigerant.
- A low charge usually indicates a leak or an incorrect installation charge.
- Operating pressures alone may not confirm the exact refrigerant quantity.
- The definitive check is to recover and weigh the refrigerant.
- Any leak must be repaired before evacuation and recharging.
- All refrigerant work must be completed by a licensed technician.