Compatibility overview: The anywAiR ducted controller can be used with the indoor units listed below. For new installations, select a compatible indoor unit and the correct anywAiR controller/accessories for that product generation. For existing installations, the indoor unit may be compatible but the existing duct layout, dampers and zoning configuration must also be checked before retrofit.
Important: The original compatibility document references controller code UTY-ANY1. Current General AIRSTAGE product pages for newer R32 ARTH models may list UTY-ANY2 as the applicable anywAiR controller. Confirm the required controller generation and accessories before ordering or modifying an existing installation.
Legacy compatible indoor units
The following models are listed in the supplied anywAiR Ducted Controller Touch Pad compatibility reference.
| Indoor Model No. | Indoor Model No. | Indoor Model No. |
|---|---|---|
| ARTG24LHTDP | ARTG30LHTDP | ARTG36LHTDP |
| ARTG45LHTDP | ARTG54LHTDP | ARTG45LDTA |
| ARTG54LDTA | ARTG60LDTA | ARTG30LHTA |
| ARTG36LHTA | ARTG45LHTA | ARTG54LHTC |
| ARTG36LHTB | ARTG45LHTB | ARTG60LHTA |
| ARTG65LHTA | ARTC72LATU | ARTC90LATU |
Original controller reference: UTY-ANY1 anywAiR ducted controller.
Current ARTH ducted models
The following ARTH models are currently listed across the ducted product ranges on the General AIRSTAGE Australia website.
Bulkhead R32
| Model | Nominal Cooling | Range |
|---|---|---|
| ARTH09KSLAP | 2.5 kW | Bulkhead R32 |
| ARTH09KLLAP | 2.5 kW | Bulkhead R32 |
| ARTH12KSLAP | 3.5 kW | Bulkhead R32 |
| ARTH12KLLAP | 3.5 kW | Bulkhead R32 |
| ARTH18KSLAP | 5.0 kW | Bulkhead R32 |
| ARTH18KLLAP | 5.0 kW | Bulkhead R32 |
Mid Static Slimline R32
| Model | Nominal Cooling | Range |
|---|---|---|
| ARTH18KMTAP | 5.0 kW | Mid Static Slimline |
| ARTH24KMTAP | 7.1 kW | Mid Static Slimline |
| ARTH30KMTAP | 8.5 kW | Mid Static Slimline |
| ARTH36KMTAP | 10.0 kW | Mid Static Slimline |
| ARTH45KMTAP | 12.5 kW | Mid Static Slimline |
| ARTH54KMTAP | 13.0 kW | Mid Static Slimline |
| ARTH24KMTAP-HP | 7.1 kW | Mid Static Slimline High Performance |
| ARTH30KMTAP-HP | 8.5 kW | Mid Static Slimline High Performance |
High Static R32
| Model | Nominal Cooling | Range |
|---|---|---|
| ARTH24KHTA | 7.1 kW | High Static Single Phase |
| ARTH30KHTA | 8.5 kW | High Static Single Phase |
| ARTH36KHTA | 10.0 kW | High Static Single Phase |
| ARTH45KHTA | 12.5 kW | High Static Single Phase |
| ARTH54KHTA | 14.0 kW | High Static Single Phase |
| ARTH60KHTA | 15.5 kW | High Static Single Phase |
| ARTH30KHTA-HP | 8.5 kW | High Static Single Phase High Performance |
| ARTH36KHTA-HP | 10.0 kW | High Static Single Phase High Performance |
| ARTH45KHTA-HP | 12.5 kW | High Static Single Phase High Performance |
| ARTH54KHTA-HP | 14.0 kW | High Static Single Phase High Performance |
| ARTH60KHTB | 16.0 kW | High Static Single Phase High Performance |
| ARTH65KHTA | 18.0 kW | Large Capacity High Static Single Phase |
| ARTH65KHTA-3PH | 18.0 kW | Large Capacity High Static Three Phase |
| ARTH72KHTA-3PH | 20.0 kW | Large Capacity High Static Three Phase |
| ARTH90KHTA-3PH | 22.4 kW | Large Capacity High Static Three Phase |
Note on model naming: Some General AIRSTAGE website range pages use suffixes such as -HP and -3PH to identify a system/range configuration. Always confirm the actual indoor unit model on the product nameplate and the required controller/accessory combination before ordering parts.
Existing installation / retrofit checks
When fitting anywAiR to an existing ducted system, indoor unit compatibility alone does not confirm that the installation can be converted without modification. Check the following:
- Confirm the exact indoor unit model from the nameplate.
- Confirm whether UTY-ANY1, UTY-ANY2 or additional interface hardware is required.
- Check the existing duct design and available airflow.
- Confirm damper type, voltage and compatibility with the proposed zoning arrangement.
- Confirm the number of zones and any required spill/bypass strategy.
- Where suitability is uncertain, refer the installation to a Fujitsu/General Authorised Partner or qualified ducted air-conditioning installer.
Website verification: The ARTH models above were checked against the current General AIRSTAGE Australia residential ducted product ranges in September 2026. Product ranges and accessory compatibility can change, so the current product page should be checked when supplying equipment for a new installation.
General Assist technical reference. Model availability and accessory requirements are subject to product revision.