ASTA12JCC / AOTR12JCC
Applies to
| Indoor unit | ASTA12JCC |
| Outdoor unit | AOTR12JCC |
| System type | Cooling-only inverter wall mounted split system |
| Refrigerant | R410A |
| Manual | 9331435017-01 |
1. Basic operation
Start the air conditioner
- Press the START/STOP button on the wireless remote control.
- Press MASTER CONTROL to select the required operating mode.
- Use SET TEMP. to adjust the temperature.
- Press FAN CONTROL to select the fan speed.
| Setting | Options / Range |
|---|---|
| Operating modes | AUTO, COOL, DRY, FAN |
| AUTO temperature | 18–30°C |
| Cooling / Dry temperature | 18–30°C |
| Fan speeds | AUTO, HIGH, MED, LOW, QUIET |
AUTO mode
When AUTO is selected, the unit checks room conditions and automatically selects cooling, dry or monitor operation to maintain the selected temperature.
2. Timer operation
Set the remote control clock to the correct current time before using timer functions.
| Timer | Function |
|---|---|
| ON Timer | Starts the air conditioner at the selected time. |
| OFF Timer | Stops the air conditioner at the selected time. |
| Program Timer | Combines one ON and one OFF timer transition within a 24-hour period. |
| Sleep Timer | Gradually increases the cooling set temperature for comfort, then stops the unit at the end of the selected period. |
To cancel a timer, use the TIMER MODE button to select CANCEL.
3. Airflow and swing
- Use the remote control SET button to adjust vertical airflow.
- Cooling and Dry modes use positions 1, 2 or 3.
- FAN mode allows positions 1 to 6.
- Horizontal right-left airflow is adjusted manually using the right-left louvers.
- Press SWING to automatically move the vertical airflow louvers up and down.
4. Manual Auto operation
If the wireless remote control is lost or unavailable, press the indoor unit MANUAL AUTO button. The unit operates using AUTO mode, AUTO fan speed and a standard thermostat setting of 24°C. Press MANUAL AUTO again to stop operation.
5. Cleaning and care
- Stop the air conditioner and disconnect the power supply.
- Open the intake grille and remove the air filters.
- Remove dust with a vacuum cleaner or wash using mild detergent and warm water.
- Allow washed filters to dry thoroughly in a shaded location.
- Refit the filters and securely close the intake grille.
During normal use, the air filters should be cleaned approximately every two weeks.
Air cleaning filters
| Filter | Part / Maintenance |
|---|---|
| Polyphenol Catechin Air Cleaning Filter | UTR-FA04-1 — disposable; replacement generally recommended about every three months. |
| Negative Air Ions Deodorizing Filter | UTR-FA04-2 — clean about every three months; replacement about every three years. |
6. Troubleshooting
| Symptom | Check / Explanation |
|---|---|
| Does not start immediately | A protection delay of approximately three minutes can occur after stopping/restarting the unit or reconnecting power. |
| Noise is heard | Refrigerant flow noises or slight expansion/contraction noises may occur during or shortly after operation. |
| Mist from indoor unit | A thin mist can occur during Cooling or Dry operation due to rapid cooling of room air. |
| Weak airflow | The fan may run at very low speed during Dry operation or while monitoring room temperature. |
| Poor cooling | Check filters, blocked intake/outlet, temperature setting, open doors/windows, direct sunlight, internal heat loads and whether LOW or QUIET fan operation is selected. |
| Remote control response differs | Check that the remote control batteries are correctly installed and are not flat. |
7. Operating limits and restart
| Mode | Outdoor temperature | Indoor temperature |
|---|---|---|
| Cooling | Approx. 18–43°C | Approx. 18–32°C |
| Dry | Approx. 18–43°C | Approx. 18–32°C |
After a power interruption, the air conditioner automatically restarts using its previous operating mode when power is restored. Timer settings may reset following a power interruption.