ASTG34LFCA / AOTG34LFT - Operation Guide

This article summarises the main operating instructions for the ASTG34LFCA wall-mounted indoor unit and its corresponding AOTG34LFT outdoor unit.

Refrigerant: This product uses R410A refrigerant. Installation, maintenance and service work must only be carried out by suitably qualified personnel in accordance with applicable regulations and service documentation.

Quick Start

  1. Turn on the circuit breaker.
  2. Press START/STOP.
  3. Press MODE to select AUTO, COOL, DRY, HEAT or FAN.
  4. Use SET TEMP. to select the required temperature.
  5. Use FAN to select AUTO, HIGH, MED, LOW or QUIET.
AUTO temperature range18-30°C
Heating temperature range16-30°C
Cooling / Dry temperature range18-30°C
Wireless remote rangeApproximately 7 m

Operating Modes

ModeOperation
AUTOAutomatically selects heating, cooling, dry or monitor operation according to room temperature and the set temperature.
COOLCools the room.
DRYGently cools while dehumidifying. Fan speed is controlled automatically and may stop intermittently.
HEATHeats the room. Fan speed may remain very low for approximately 3-5 minutes after start-up while the indoor unit warms.
FANCirculates room air without heating or cooling.

Auto Changeover

When AUTO is first selected, the fan operates at very low speed for a few minutes while the unit assesses room conditions and selects the appropriate operating mode.

  • More than approximately +2°C above the set temperature: Cooling or Dry.
  • Within approximately ±2°C of the set temperature: Mode is determined according to outdoor conditions / monitor operation.
  • More than approximately -2°C below the set temperature: Heating.

Fan Speed and Super Quiet

Fan speed selections are AUTO, HIGH, MED, LOW and QUIET.

  • During heating, AUTO fan speed is reduced while discharge air is still cool.
  • During cooling, fan speed reduces as room temperature approaches the set temperature.
  • During monitor operation and at the start of heating, the fan may operate at very low speed.
  • SUPER QUIET reduces airflow and may reduce heating or cooling performance.
  • SUPER QUIET cannot be used during DRY mode.

10°C Heat Operation

Press 10°C HEAT to maintain the room at approximately 10°C and help prevent the space from becoming excessively cold.

  • The heating function will not operate if room temperature is already high enough.
  • During 10°C Heat operation, only vertical and horizontal airflow adjustment are available from the wireless remote.
  • Press START/STOP to cancel 10°C Heat.

Economy Operation

Press ECONOMY to reduce energy use.

  • At maximum output, Economy operation is approximately 70% of normal operation for cooling and heating.
  • During cooling, the controlled room temperature is slightly higher than the set temperature.
  • During heating, the controlled room temperature is slightly lower than the set temperature.
  • Economy does not activate during monitor operation in AUTO mode.

Timer Functions

  • ON Timer
  • OFF Timer
  • Program Timer
  • SLEEP Timer

ON / OFF Timer

  1. Press TIMER MODE to select ON or OFF.
  2. Use TIMER SET to select the required time.
  3. The orange TIMER indicator on the indoor unit will illuminate.

Program Timer

The Program Timer combines one ON timer and one OFF timer into a single sequence within a 24-hour period.

Sleep Timer

The SLEEP timer automatically adjusts the thermostat setting to reduce excessive heating or cooling while sleeping, then stops the air conditioner when the selected time expires.

  • Cooling / Dry: Set temperature rises by 1°C each hour to a maximum increase of 2°C.
  • Heating: Set temperature drops by 1°C every 30 minutes to a maximum reduction of 4°C.

Airflow Direction

Vertical and horizontal airflow direction can both be adjusted from the wireless remote controller.

  • Use SET (Vertical) to adjust up/down airflow.
  • Use SET (Horizontal) to adjust left/right airflow.
  • The unit automatically selects horizontal airflow in cooling/dry and downward airflow in heating.
Cooling / Dry: Do not leave the vertical louvers in heating positions 4-6 for extended periods. If left there for more than approximately 20 minutes, the unit automatically returns them to position 3 to reduce condensation risk.

Swing Operation

  • Up/down swing
  • Left/right swing
  • Combined up/down and left/right swing
  • Press SWING until STOP is selected to return airflow to the previous fixed position.
  • Swing may pause when the fan is stopped or operating at very low speed.

Manual Auto Operation

Use MANUAL AUTO if the wireless remote controller is lost or unavailable.

  • Press and hold MANUAL AUTO for more than 3 seconds and less than 10 seconds to start operation.
  • The unit operates in AUTO mode.
  • Fan speed is set to AUTO.
  • Temperature setting is approximately 24°C.
  • Press MANUAL AUTO again to stop.
  • Holding the button for more than 10 seconds starts Forced Cooling for authorised service use.

Remote Controller Signal Code

Where two or more air conditioners are installed in the same room, the wireless remote can be assigned one of four signal codes.

  1. Press START/STOP until only the clock is shown.
  2. Hold MODE for at least 5 seconds.
  3. Use the temperature buttons to select the required signal code.
  4. Press MODE again to save.
Factory default: The indoor unit and remote controller are set to signal code A.

Optional Wired Remote Controller

An optional wired remote controller can be used together with the wireless remote controller.

Additional wired-controller functions:

  • Weekly timer
  • Temperature setback timer

Wireless functions restricted when a wired controller is used:

  • 10°C Heat
  • ON / OFF / Program timers
  • SLEEP Timer

Automatic Defrosting

During heating in low outdoor temperatures and high humidity, frost may form on the outdoor unit. The system automatically enters a defrost cycle to restore performance.

  • Heating temporarily stops during defrost.
  • The OPERATION indicator flashes.
  • Automatic defrost may operate for up to approximately 15 minutes.
  • Steam or water from the outdoor unit during defrost is normal.

Cleaning and Care

Before cleaning: Stop the air conditioner and disconnect the power supply.
  • Clean the standard air filters approximately every 2 weeks.
  • Remove dust with a vacuum cleaner or wash using mild detergent and warm water.
  • Allow filters to dry fully in a shaded area before reinstalling.
  • Do not use water hotter than 40°C, abrasive cleaners, benzene or thinner.
  • If the unit will be unused for 1 month or more, run FAN mode for approximately half a day before shutdown to dry internal components.

Air Cleaning Filters

FilterPart NumberMaintenance
Polyphenol Catechin Air Cleaning FilterUTR-FA13-1Disposable; replace approximately every 3 months
Negative Air Ions Deodorizing FilterUTR-FA13-2Clean approximately every 3 months; replace approximately every 3 years

Filter Indicator Reset

Where the optional filter indicator has been enabled during installation, clean the filters and then press the indoor unit MANUAL AUTO button for 2 seconds or less to reset the indicator.

Normal Operating Characteristics

  • Approximately 3-minute compressor delay after restarting or restoring power.
  • Refrigerant-flow sounds during operation or shortly after stopping.
  • Slight squeaking from expansion and contraction of the front panel.
  • A sizzling sound during automatic defrost.
  • Odours previously absorbed from the room may be emitted.
  • Mist during Cooling or Dry operation.
  • Steam or water from the outdoor unit during defrost.
  • Very low airflow at the start of heating or during monitor operation.
  • Indoor operation may stop temporarily during automatic defrost.

Troubleshooting

Unit Does Not Operate

  • Check whether the circuit breaker is ON.
  • Check for a power failure.
  • Check whether a fuse has blown or circuit breaker has tripped.
  • Check whether a timer is controlling operation.

Poor Cooling or Heating Performance

  • Check whether the air filter is dirty.
  • Check whether the intake grille or outlet is blocked.
  • Confirm the thermostat setting is appropriate.
  • Check whether windows or doors are open.
  • During cooling, check for strong direct sunlight.
  • Check for high internal heat loads or excessive room occupancy.
  • Check whether SUPER QUIET is selected.

Remote Controller Does Not Operate Correctly

  • Check whether the remote-controller batteries are flat.
  • Confirm the batteries are installed with the correct polarity.
Stop operation and isolate power immediately if there is a burning smell or other abnormal condition. If the OPERATION and TIMER indicators flash and the ECONOMY indicator flashes rapidly, contact authorised service personnel.