This article summarises the operating instructions for the ASTG09CMCA wall-mounted indoor unit. The operating manual also covers ASTG07CMCA and ASTG12CMCA models. The matched outdoor model for this article is AOTG09CMCA.
- Refrigerant: R32
- Operating modes: AUTO, COOL, DRY and FAN
- Temperature setting range: 18-30°C in AUTO / COOL / DRY
- Fan speeds: AUTO, HIGH, MED, LOW and QUIET
- Remote-control operating range: approximately 7 m
- Weekly timer: up to 4 programs per day / 28 per week
- Human Sensor Energy Saving: enabled from factory
Basic Operation
- Press START/STOP.
- Press MODEto select:
- AUTO
- COOL
- DRY
- FAN
- Use the TEMP buttons to set the required temperature.
Temperature adjustment is available from 18-30°C in AUTO, COOL and DRY modes. Temperature control is not available in FAN mode.
Fan Speed
Press the FAN button to cycle through:
- AUTO
- HIGH
- MED
- LOW
- QUIET
When AUTO fan speed is selected, fan speed is adjusted automatically according to the operating mode.
Airflow Direction and Swing
- Press SET to change the vertical airflow direction.
- Press SWING to start or stop automatic vertical louvre swing.
- Horizontal airflow direction is adjusted manually using the two louvre knobs.
POWERFUL Operation
Press POWERFUL to operate the system at maximum output and strong airflow for rapid cooling.
- The indoor unit gives 3 short beeps when POWERFUL starts.
- Press POWERFUL again to cancel; the unit gives 2 short beeps.
- POWERFUL may cancel automatically after approximately 20 minutes or once the set temperature is reached.
- POWERFUL cannot operate simultaneously with ECONOMY.
- POWERFUL overrides Outdoor Unit Low Noise and Energy Saving while active.
ECONOMY Operation
Press ECONOMY to reduce energy consumption.
- In COOL or DRY mode, the room temperature is controlled a few degrees higher than the set temperature.
- Maximum output during ECONOMY operation is approximately 70% of normal operation.
Outdoor Unit Low Noise
Press OUTDOOR UNIT LOW NOISE to reduce outdoor-unit operating noise by reducing compressor speed and fan speed.
- The setting remains stored until cancelled.
- It cannot be used simultaneously with FAN, DRY or POWERFUL operation.
Manual Operation Without the Remote
The indoor-unit MANUAL AUTO button can be used if the remote controller is unavailable.
| Unit Status | Button Action | Result |
|---|---|---|
| Operating | Press more than 3 seconds | Stop |
| Stopped | Press more than 3 sec and less than 10 sec | AUTO operation |
| Stopped | Press more than 10 seconds | Forced cooling - servicing only |
| After filter cleaning | Press less than 3 seconds | Filter indicator reset |
Timer Functions
ON / OFF Timer
- Press TIMER SETTING.
- Use SELECT to choose ON, OFF, ON/OFF program, or SLEEP.
- Press NEXT.
- Set the required time using SELECT.
- Press SEND close to the indoor unit.
SLEEP Timer
Available timer periods are:
0.5, 1, 2, 3, 5, 7 or 9 hours.
WEEKLY Timer
- Up to 4 ON/OFF programs per day.
- Up to 28 programs per week.
- Temperature can be programmed with an ON event.
- Clock and day must be set correctly before using the Weekly Timer.
A power interruption can reset the timer clock. When power returns, the TIMER indicator may blink. Reset the date, time and timer settings as required.
Human Sensor - Energy Saving
The Human Sensor Energy Saving program is ON from the factory.
- Press SENSOR to enable or disable the function.
- If no person is detected for approximately 20 minutes, the system automatically modifies the temperature setting.
- In COOL / DRY mode, the set temperature may increase by up to approximately 2°C.
- Normal settings return when the sensor detects someone re-entering the room.
The sensor detection range shown in the manual is approximately 7 m, with approximately 100° horizontal coverage and 90° vertical coverage.
Demand Response
The system supports Air Conditioning Demand Response where enabled by the electricity supplier.
| DR Mode | Operation |
|---|---|
| DR Mode 1 | Compressor OFF |
| DR Mode 2 | Electrical energy consumption limited to no more than 50% of rated half-hour consumption |
| DR Mode 3 | Electrical energy consumption limited to no more than 75% of rated half-hour consumption |
The indoor OPERATION indicator blinks while Demand Response is active.
Operating Temperature and Humidity
- COOL / DRY indoor temperature: approximately 18-32°C
- Indoor humidity: below approximately 80% RH
Filter Cleaning
Clean the air filters approximately once every 2 weeks under normal use.
- Open the intake grille.
- Remove the filters.
- Vacuum or wash with warm water and neutral household detergent.
- Rinse thoroughly.
- Dry completely in a shaded location.
- Refit the filters and close the intake grille fully.
Air Cleaning Filters
| Filter | Part Number | Maintenance |
|---|---|---|
| Apple-catechin filter | UTR-FA16 | Disposable. Replace approximately every 3 months. |
| Ion deodorization filter | UTR-FA16-2 | Clean approximately every 3 months; replace approximately every 3 years. |
Normal Operating Characteristics
The following conditions may be normal and do not necessarily indicate a fault:
- Compressor operation delayed for approximately 3 minutes after a sudden power OFF/ON.
- Refrigerant-flow noise for 2-3 minutes after startup.
- Light squeaking caused by thermal expansion and contraction of the front panel.
- Mist during COOL or DRY operation.
- Very low or stopped indoor airflow during DRY mode or monitoring operation.
- Reduced airflow when QUIET fan mode is selected.
Troubleshooting
Unit Does Not Operate
- Check circuit breaker and power supply.
- Check for a power outage or blown fuse.
- Check whether a timer is preventing operation.
Poor Cooling
- Clean dirty air filters.
- Check that the indoor intake and outlet are not obstructed.
- Confirm the temperature setting is appropriate.
- Close open windows and doors.
- Check for excessive sunlight or internal heat loads.
- Check whether fan speed is set to QUIET.
- Check whether Outdoor Unit Low Noise is active.
- Check whether the electricity supplier is applying Demand Response.
Remote Controller Does Not Operate Correctly
- Check the batteries.
- Confirm battery polarity.
- Ensure there are no obstructions between the remote and indoor receiver.
- There is a burning smell or smoke.
- Water is leaking from the unit.
- The problem remains after the basic checks above.
- The OPERATION and TIMER indicators blink while the ECONOMY indicator flashes rapidly.