ASTG18KMCB / ASTG22KMCB / ASTG24KMCB
1. Quick operation
| Function | Operation |
|---|---|
| Start / Stop | Press START/STOP. |
| Operating mode | Press MODE: AUTO → COOL → DRY → FAN → HEAT. |
| Temperature | AUTO / COOL / DRY: 18–30 °C. HEAT: 16–30 °C. Temperature control is not available in FAN mode. |
| Fan speed | AUTO → HIGH → MED → LOW → QUIET. |
POWERFUL operation
POWERFUL operation runs the system at maximum power and strong airflow to cool or heat the room quickly. It automatically ends when the room reaches the set temperature or after approximately 20 minutes. POWERFUL cannot operate at the same time as ECONOMY, and it temporarily overrides Outdoor Unit Low Noise and Energy Saving functions.
10 °C HEAT
10 °C HEAT maintains the room at approximately 10 °C to help prevent the temperature falling too low. The ECONOMY indicator turns green while this function is active. Only vertical airflow direction can be adjusted during 10 °C HEAT.
Outdoor Unit Low Noise
This function reduces outdoor-unit noise by lowering compressor rotation and outdoor fan speed. The setting is retained even after the indoor unit is stopped. It cannot be used together with FAN, DRY or POWERFUL operation.
2. Airflow direction and swing
These models provide both vertical and horizontal motorised airflow control.
| Control | Available positions / operation |
|---|---|
| Vertical airflow | 8 positions using the Vertical SET button. |
| Horizontal airflow | 5 positions using the Horizontal SET button. |
| SWING | Cycles through Up/Down, Left/Right, Up/Down + Left/Right, and Stop Swing. |
3. Timer operation
Before setting timers, make sure the remote controller clock and day of the week are correct.
| Timer | Purpose |
|---|---|
| ON timer | Starts the unit at the selected time. |
| OFF timer | Stops the unit at the selected time. |
| Program timer | Combines ON and OFF timing within a 24-hour period. |
| Sleep timer | Gradually adjusts temperature for comfort, then turns the air conditioner off after the selected period. |
| Weekly timer | Up to 4 ON/OFF reservations per day and up to 28 reservations per week. |
ON / OFF timer setup
- Press TIMER SETTING.
- Use SELECT to choose ON, OFF or ON↔OFF.
- Press NEXT.
- Use SELECT to set the time.
- Press SEND while close to the indoor unit.
Weekly timer
The Weekly Timer supports four programs per day. Each program can be set as ON, OFF or unused. For ON programs, a temperature can also be specified. AUTO / COOL / DRY can be set from 18–30 °C; HEAT can be set to 10 °C or 16–30 °C.
4. Energy-saving functions
ECONOMY
ECONOMY reduces maximum output to approximately 70% of normal operation and moderates the room temperature. In COOL / DRY, the room is controlled a few degrees warmer than the set temperature; in HEAT, a few degrees cooler.
Human Sensor Energy Saving
The Energy Saving program is enabled at the factory. If no movement is detected for approximately 20 minutes, the set temperature is adjusted to reduce energy use. When someone returns, the unit automatically returns to the original setting.
| Mode | No person detected |
|---|---|
| COOL / DRY | Set temperature increases by up to approximately 2 °C. |
| HEAT | Set temperature decreases by up to approximately 4 °C. |
| AUTO | Energy-saving behaviour follows the active cooling, heating or dry mode. |
The sensor detects infrared movement and has an approximate range of 7 m, 90° vertically and 100° horizontally. Detection may be affected by room temperature, people remaining still, furniture, glass, thick clothing, pets, moving curtains, plants, heaters, humidifiers and oscillating fans.
Demand Response
The system supports Air Conditioning Demand Response where available through the electricity supplier. When active, the OPERATION indicator blinks and cooling or heating capacity can be reduced.
| DR mode | Operation |
|---|---|
| DR1 | Compressor off. |
| DR2 | Energy consumption limited to no more than 50% of rated energy consumption over a half-hour period. |
| DR3 | Energy consumption limited to no more than 75% of rated energy consumption over a half-hour period. |
5. Remote control, wired control and Wireless LAN
Remote controller custom code
Where two or more air conditioners are installed in the same room, the wireless remote controller can be assigned one of four custom codes: A, B, C or D. The indoor unit and remote controller must use the same code. Both are set to code A from the factory.
- Stop operation so only the clock is shown on the remote controller.
- Press and hold MODE for at least 5 seconds to display the current custom code.
- Use the temperature buttons to select A, B, C or D.
- Press MODE again to return to the clock display.
Optional wired remote controller
An optional wired remote controller can be used with the wireless remote. Some wireless functions become restricted depending on the wired controller type.
| Wired controller type | Restricted wireless functions |
|---|---|
| Polar 3-core | Outdoor Unit Low Noise, Energy Saving, 10 °C HEAT, POWERFUL and timer operation. |
| Non-polar 2-core | Outdoor Unit Low Noise, 10 °C HEAT, Weekly Timer and POWERFUL. |
Built-in Wireless LAN control
The WLAN adapter is built into the indoor unit. The manual directs users to the dedicated Wireless LAN setting manual for connection and app configuration. The Wireless LAN indicators can be turned off through the mobile app.
TEST RUN button
The TEST RUN button is for initial installation testing only and should not be used during normal operation. During Test Run, the OPERATION and TIMER indicators blink simultaneously. If started accidentally, stop the unit using the Start/Stop button.
6. Cleaning and maintenance
Under normal use, clean the air filters approximately every 2 weeks. Dust can be removed with a vacuum cleaner, or the filters can be washed using neutral household detergent and warm water. Dry them thoroughly in the shade before refitting.
| Air cleaning filter | Part number / maintenance |
|---|---|
| Apple-catechin filter | UTR-FA16. Disposable; do not wash or reuse. Replace approximately every 3 months under normal use. |
| Ion deodorization filter | UTR-FA16-2. Clean approximately every 3 months and replace approximately every 3 years under normal use. |
If the indoor unit has not been used for one month or more, run FAN mode for half a day to dry the internal components before returning to normal operation.
7. Normal operating characteristics
- Restart delay: Compressor start can be delayed by approximately 3 minutes after a sudden OFF → ON power change.
- Defrost: Heating may stop for up to approximately 15 minutes while the outdoor unit defrosts. The OPERATION indicator blinks.
- Water / steam outdoors: Water or steam can be produced during heating defrost and is normal.
- Low airflow in heating: Fan speed may remain very low during warm-up or when room temperature is above the set temperature.
- Dry mode: Indoor fan operates at low speed and may stop intermittently for humidity control.
- Noise: Refrigerant flow, panel expansion/contraction and sizzling during defrost can be normal.
8. Troubleshooting
| Symptom | Checks |
|---|---|
| Does not operate | Check breaker, power outage, fuse / circuit breaker trip and timer settings. |
| Poor cooling or heating | Check dirty filters, blocked inlet/outlet, temperature setting, open doors/windows, direct sunlight, internal heat loads, QUIET fan speed, Outdoor Unit Low Noise and Demand Response operation. |
| Different from remote setting | Check remote-control batteries and battery installation. |
| Airflow weak or stopped | May be normal during heating warm-up, defrost, DRY mode, QUIET mode, AUTO monitoring or when the outdoor unit has stopped. |