General Assist Technical Reference

ASTG09KMCB / ASTG12KMCB

Operation, timers, energy-saving functions, care and troubleshooting
Wall-mounted R32 split-system air conditioners
This guide summarises the main day-to-day operating functions for ASTG09KMCB and ASTG12KMCB, including remote-controller operation, built-in wireless LAN capability, timers, Human Sensor energy saving, Demand Response, cleaning and common operating characteristics.
R32 refrigerant: This product uses flammable refrigerant R32. Installation, relocation, refrigerant work and servicing must only be carried out by appropriately qualified personnel in accordance with applicable regulations and service instructions.

1. Quick start

FunctionAction
Start / stopPress START/STOP.
Select modePress MODE: AUTO → COOL → DRY → FAN → HEAT.
Set temperatureUse the TEMP ▲ / ▼ buttons. AUTO/COOL/DRY: 18–30 °C. HEAT: 16–30 °C.
Fan speedPress FAN: AUTO → HIGH → MED → LOW → QUIET.
Vertical airflowPress SET to adjust the vertical louvre. Press SWING to start or stop automatic vertical swing.
Heating start-up: In HEAT mode, the indoor fan may operate at very low speed for approximately 3–5 minutes while the unit warms internally. This is normal.

2. Remote controller functions

ButtonFunctionKey notes
POWERFULRuns at maximum power and strong airflow for rapid cooling or heating.Turns off automatically after approximately 20 minutes or when set conditions are reached. Cannot operate with ECONOMY.
10 °C HEATMaintains the room at approximately 10 °C to prevent it becoming excessively cold.ECONOMY indicator illuminates. Only vertical airflow can be adjusted. Heating will not operate if the room is already warm enough.
OUTDOOR UNIT LOW NOISEReduces compressor rotation and outdoor fan speed.Setting is retained until cancelled. Not available with FAN, DRY or POWERFUL operation.
ECONOMYModerates the temperature setting to reduce energy use.Maximum output is approximately 70% of normal operation in COOL, HEAT or DRY.
SENSORTurns the Human Sensor Energy Saving Program on or off.Energy Saving is enabled by default from the factory.
TEST RUNUsed only for the initial installation test.Do not use during normal operation. During test run, the OPERATION and TIMER indicators blink together. Press START/STOP to cancel an accidental test run.
Remote-controller range: Aim the transmitter at the indoor-unit receiver. Normal operating range is approximately 7 metres. A confirmation beep should be heard when the signal is received.

Manual Auto operation

If the remote controller is lost or unavailable, use the MANUAL AUTO button on the indoor unit:

Unit operatingPress for more than 3 seconds to stop.
Unit stoppedPress for more than 3 seconds but less than 10 seconds to start AUTO operation.
Service usePress for more than 10 seconds to force cooling. This is intended for servicing.
After filter cleaningPress for less than 3 seconds to reset the filter indicator.

3. Wireless LAN, custom code and controller options

Built-in wireless LAN control

The ASTG09KMCB and ASTG12KMCB indoor units have a built-in wireless LAN adapter. The indoor unit includes wireless LAN control indicators and buttons.

For wireless LAN setup, pairing and app operation, refer to the dedicated Wireless LAN setting manual. The operating manual notes that the wireless LAN indicators can be turned off using the mobile app.

Remote controller custom code A / B / C / D

If two or more air conditioners are installed in the same room and one remote controller operates the wrong unit, the remote controller can be assigned one of four custom codes. The indoor unit must be configured to the matching code by service personnel.

  1. Press START/STOP until only the clock is displayed.
  2. Press and hold MODE for at least 5 seconds to display the current custom code. The factory setting is A.
  3. Use the TEMP ▲ / ▼ buttons to select A, B, C or D.
  4. Press MODE again to return to the clock display.
The remote controller and indoor unit must use the same custom code. On some remote controllers the code may return to A after the batteries are replaced, so the code may need to be reselected.

Optional wired remote controller

An optional wired remote controller can be used, including together with the wireless remote controller. The wired controller adds a temperature setback timer; however, some wireless-remote functions must be disabled when a polar 3-core wired remote controller is used.

Restricted wireless functionsNotes
Outdoor Unit Low NoiseThese functions are listed as restricted in the operating manual when the polar 3-core wired controller is used. If the restriction setup is incorrect, the indoor unit may beep and the OPERATION, TIMER and ECONOMY indicators may flash.
Energy Saving
10 °C HEAT
POWERFUL
Timer operation

4. Timer operation

Before using timers, make sure the remote controller clock and day are correct. A power interruption can make the internal clock incorrect and cause the TIMER indicator to blink.

ON / OFF timer

  1. Press TIMER SETTING.
  2. Use SELECT to choose ON/OFF timer and press NEXT.
  3. Set the required time with SELECT.
  4. Press SEND while close to the indoor unit.

Program timer

The ON timer and OFF timer can be combined as an ON→OFF or OFF→ON sequence within a 24-hour period. The timer closest to the current time operates first.

Sleep timer

The SLEEP timer gradually adjusts the set temperature to reduce excessive heating or cooling while sleeping, then switches the unit off after the selected duration.

Weekly timer

The WEEKLY timer supports up to 4 ON/OFF reservations per day and 28 reservations per week. Temperature can be included with ON settings.
  1. Enter TIMER SETTING and select WEEKLY.
  2. Select the required day and program number.
  3. Select ON timer, OFF timer or no timer.
  4. Set the required time.
  5. For an ON event, set the required temperature.
  6. Press SEND to save.
The WEEKLY timer cannot be used at the same time as ON/OFF, Program or SLEEP timer operation. If another timer is used, the WEEKLY timer must be activated again afterwards.

5. Human Sensor and energy saving

The Human Sensor detects movement in the room and can automatically moderate the temperature when nobody is detected for approximately 20 minutes.

ModeWhen no-one is detected
COOL / DRYSet temperature may increase by up to approximately 2 °C.
HEATSet temperature may decrease by up to approximately 4 °C.
AUTOEnergy Saving operates automatically according to the active mode.

The sensor has an approximate 7 m range, with a vertical detection angle of 90° and horizontal angle of 100°. Detection may be affected when people remain still, are obscured by furniture, or when moving pets, curtains, plants or appliances are within the sensing area.

Demand Response

These models are compatible with an electricity-supplier Demand Response program where available. During a Demand Response event the indoor OPERATION indicator blinks and the system may have its compressor disabled or its electricity consumption limited.

DR modeOperation
DR 1Compressor off.
DR 2Energy consumption is limited to no more than 50% of the energy that would be consumed at rated capacity over a half-hour period.
DR 3Energy consumption is limited to no more than 75% of the energy that would be consumed at rated capacity over a half-hour period.

6. Normal operating characteristics

3-minute restart delayAfter a sudden OFF→ON restart, the compressor may remain stopped for about 3 minutes for protection.
Automatic defrostDuring heating in cold/humid conditions, operation may stop temporarily for up to approximately 15 minutes while the outdoor unit defrosts. The OPERATION indicator blinks.
Steam / water outdoorsSteam or water from the outdoor unit during heating/defrost is normal.
Low airflow in heatingThe fan may operate very slowly while the indoor heat exchanger warms or when room temperature is above the set temperature.
Auto restartAfter a power interruption, the system normally restarts automatically in the previous operating mode. Timer settings may require resetting.

Indoor operating range

ModeIndoor conditions
COOL / DRYApproximately 18–32 °C; humidity below approximately 80%.
HEATApproximately 16–30 °C.

7. Care and cleaning

Before cleaning the indoor unit, stop operation and disconnect the power supply. Do not touch the aluminium heat-exchanger fins.

Air filters should be cleaned approximately every 2 weeks under normal use. A clogged filter can reduce airflow, lower performance and increase operating noise.

  1. Open the intake grille.
  2. Release the filter claws and remove each air filter.
  3. Remove the air-cleaning filter holders from the rear of the filters.
  4. Vacuum the filter, or wash it using warm water and a neutral household detergent.
  5. Dry completely in the shade.
  6. Refit the filter and ensure the retaining claws are correctly engaged.
  7. Close the intake grille completely.

Optional air-cleaning filters

FilterPart numberMaintenance
Apple-catechin filterUTR-FA16Disposable. Do not wash or reuse. Replace approximately every 3 months under normal use.
Ion deodorisation filterUTR-FA16-2Clean approximately every 3 months and replace approximately every 3 years under normal use.

8. Troubleshooting

SymptomCheck
Does not operateCheck circuit breaker, power outage, fuse/breaker trip and active timer settings.
Poor cooling or heatingCheck filters, blocked inlet/outlet, temperature setting, open windows/doors, direct sunlight, other heat loads, QUIET fan mode, Outdoor Unit Low Noise mode and Demand Response.
Remote operation differsCheck battery condition and polarity.
TIMER indicator blinking after outageReset the clock and timer settings.
Wireless LAN issueUse the dedicated Wireless LAN setting manual or the installed mobile app for wireless LAN troubleshooting. This operating manual does not provide the pairing or network troubleshooting procedure.
Stop operation and isolate power immediately if there is a burning smell, smoke, water leakage, or if the problem continues after basic checks. If the OPERATION and TIMER indicators blink while the ECONOMY indicator is blinking rapidly, service attention is required.
Reference models: ASTG09KMCB and ASTG12KMCB. Operating manual Part No. 9333003283.