General Assist Technical Reference

ASTG09KMCA / ASTG12KMCA

Operation, timers, energy-saving functions, care and troubleshooting
Wall-mounted R32 split-system air conditioners
This guide summarises the main day-to-day operating functions for ASTG09KMCA and ASTG12KMCA, including remote-controller operation, timers, Human Sensor energy saving, Demand Response, cleaning and common operating characteristics.
R32 refrigerant: This product uses flammable refrigerant R32. Installation, relocation, refrigerant work and servicing must only be carried out by appropriately qualified personnel in accordance with applicable regulations and service instructions.

1. Quick start

FunctionAction
Start / stopPress START/STOP.
Select modePress MODE: AUTO → COOL → DRY → FAN → HEAT.
Set temperatureUse the TEMP ▲ / ▼ buttons. AUTO/COOL/DRY: 18–30 °C. HEAT: 16–30 °C.
Fan speedPress FAN: AUTO → HIGH → MED → LOW → QUIET.
Vertical airflowPress SET to adjust the vertical louvre. Press SWING to start or stop automatic vertical swing.
Heating start-up: In HEAT mode, the indoor fan may operate at very low speed for approximately 3–5 minutes while the unit warms internally. This is normal.

2. Remote controller functions

ButtonFunctionKey notes
POWERFULRuns at maximum power and strong airflow for rapid cooling or heating.Turns off automatically after approximately 20 minutes or when set conditions are reached. Cannot operate with ECONOMY.
10 °C HEATMaintains the room at approximately 10 °C to prevent it becoming excessively cold.ECONOMY indicator illuminates. Only vertical airflow can be adjusted. Heating will not operate if the room is already warm enough.
OUTDOOR UNIT LOW NOISEReduces compressor rotation and outdoor fan speed.Setting is retained until cancelled. Not available with FAN, DRY or POWERFUL operation.
ECONOMYModerates the temperature setting to reduce energy use.Maximum output is approximately 70% of normal operation in COOL, HEAT or DRY.
SENSORTurns the Human Sensor Energy Saving Program on or off.Energy Saving is enabled by default from the factory.
Remote-controller range: Aim the transmitter at the indoor-unit receiver. Normal operating range is approximately 7 metres. A confirmation beep should be heard when the signal is received.

Manual Auto operation

If the remote controller is lost or unavailable, use the MANUAL AUTO button on the indoor unit:

Unit operatingPress for more than 3 seconds to stop.
Unit stoppedPress for more than 3 seconds but less than 10 seconds to start AUTO operation.
Service usePress for more than 10 seconds to force cooling. This is intended for servicing.
After filter cleaningPress for less than 3 seconds to reset the filter indicator.

3. Timer operation

Before using timers, make sure the remote controller clock and day are correct. A power interruption can make the internal clock incorrect and cause the TIMER indicator to blink.

ON / OFF timer

  1. Press TIMER SETTING.
  2. Use SELECT to choose ON/OFF timer and press NEXT.
  3. Set the required time with SELECT.
  4. Press SEND while close to the indoor unit.

Program timer

The ON timer and OFF timer can be combined as an ON→OFF or OFF→ON sequence within a 24-hour period. The timer closest to the current time operates first.

Sleep timer

The SLEEP timer gradually adjusts the set temperature to reduce excessive heating or cooling while sleeping, then switches the unit off after the selected duration.

Weekly timer

The WEEKLY timer supports up to 4 ON/OFF reservations per day and 28 reservations per week. Temperature can be included with ON settings.
  1. Enter TIMER SETTING and select WEEKLY.
  2. Select the required day and program number.
  3. Select ON timer, OFF timer or no timer.
  4. Set the required time.
  5. For an ON event, set the required temperature.
  6. Press SEND to save.
The WEEKLY timer cannot be used at the same time as ON/OFF, Program or SLEEP timer operation. If another timer is used, the WEEKLY timer must be activated again afterwards.

4. Human Sensor and energy saving

The Human Sensor detects movement in the room and can automatically moderate the temperature when nobody is detected for approximately 20 minutes.

ModeWhen no-one is detected
COOL / DRYSet temperature may increase by up to approximately 2 °C.
HEATSet temperature may decrease by up to approximately 4 °C.
AUTOEnergy Saving operates automatically according to the active mode.

The sensor has an approximate 7 m range, with a vertical detection angle of 90° and horizontal angle of 100°. Detection may be affected when people remain still, are obscured by furniture, or when moving pets, curtains, plants or appliances are within the sensing area.

Demand Response

These models are compatible with an electricity-supplier Demand Response program where available. During a Demand Response event the indoor OPERATION indicator blinks and the system may have its compressor disabled or its electricity consumption limited.

DR modeOperation
DR 1Compressor off.
DR 2Energy consumption is limited to no more than 50% of the energy that would be consumed at rated capacity over a half-hour period.
DR 3Energy consumption is limited to no more than 75% of the energy that would be consumed at rated capacity over a half-hour period.

5. Normal operating characteristics

3-minute restart delayAfter a sudden OFF→ON restart, the compressor may remain stopped for about 3 minutes for protection.
Automatic defrostDuring heating in cold/humid conditions, operation may stop temporarily for up to approximately 15 minutes while the outdoor unit defrosts. The OPERATION indicator blinks.
Steam / water outdoorsSteam or water from the outdoor unit during heating/defrost is normal.
Low airflow in heatingThe fan may operate very slowly while the indoor heat exchanger warms or when room temperature is above the set temperature.
Auto restartAfter a power interruption, the system normally restarts automatically in the previous operating mode. Timer settings may require resetting.

Indoor operating range

ModeIndoor conditions
COOL / DRYApproximately 18–32 °C; humidity below approximately 80%.
HEATApproximately 16–30 °C.

6. Care and cleaning

Before cleaning the indoor unit, stop operation and disconnect the power supply. Do not touch the aluminium heat-exchanger fins.

Air filters should be cleaned approximately every 2 weeks under normal use. A clogged filter can reduce airflow, lower performance and increase operating noise.

  1. Open the intake grille.
  2. Release the filter claws and remove each air filter.
  3. Remove the air-cleaning filter holders from the rear of the filters.
  4. Vacuum the filter, or wash it using warm water and a neutral household detergent.
  5. Dry completely in the shade.
  6. Refit the filter and ensure the retaining claws are correctly engaged.
  7. Close the intake grille completely.

Optional air-cleaning filters

FilterPart numberMaintenance
Apple-catechin filterUTR-FA16Disposable. Do not wash or reuse. Replace approximately every 3 months under normal use.
Ion deodorisation filterUTR-FA16-2Clean approximately every 3 months and replace approximately every 3 years under normal use.

7. Troubleshooting

SymptomCheck
Does not operateCheck circuit breaker, power outage, fuse/breaker trip and active timer settings.
Poor cooling or heatingCheck filters, blocked inlet/outlet, temperature setting, open windows/doors, direct sunlight, other heat loads, QUIET fan mode, Outdoor Unit Low Noise mode and Demand Response.
Remote operation differsCheck battery condition and polarity.
TIMER indicator blinking after outageReset the clock and timer settings.
Stop operation and isolate power immediately if there is a burning smell, smoke, water leakage, or if the problem continues after basic checks. If the OPERATION and TIMER indicators blink while the ECONOMY indicator is blinking rapidly, service attention is required.
Reference models: ASTG09KMCA and ASTG12KMCA. Operating manual Part No. 9333003016.