General Assist Technical Reference

Standby Power

Standby and pre-heat power consumption reference
Fujitsu General residential, commercial and VRF systems
The tables below provide the recorded standby power consumption for the listed Fujitsu General systems. Where applicable, separate values are shown for cooling standby, heating standby, pre-heat power and the temperature at which pre-heat is initiated.
Important: Pre-heat power is different from normal standby power. On applicable reverse-cycle and VRF systems, additional power may be consumed by crankcase or compressor heating when the relevant initiation condition is met.
Indoor modelOutdoor modelStandby - Cool (W)Standby - Heat (W)Pre-heat - Heat (W)Pre-heat initiation
ASTG - Inverter Wall Mounted - Cooling Only - R32
ASTG07CMCAAOTG07CMCA4.49---
ASTG09CMCAAOTG09CMCA4.49---
ASTG12CMCAAOTG12CMCA4.49---
ASTG18CMCAAOTG18CMCA4.17---
ASTG24CMCAAOTG24CMCA4.17---
ASTG - Inverter Wall Mounted - Reverse Cycle - R32
ASTG09KMCAAOTG09KMCA4.494.5528.755°C
ASTG12KMCAAOTG12KMCA4.494.5528.755°C
ASTG18KMCAAOTG18KMCA4.174.2237.140°C
ASTG22KMCAAOTG22KMCA4.174.2237.140°C
ASTG24KMCAAOTG24KMCA4.174.2237.140°C
ASTG - Designer Range - Reverse Cycle - R32
ASTG09KUCAAOTG09KUCA4.494.5528.755°C
ASTG12KUCAAOTG12KUCA4.494.5528.755°C
ASTG18KUCAAOTG18KUCA4.174.2237.140°C
ASTG - Inverter Wall Mounted - Cooling Only - R410A
ASTG07JECBAOTG07JECB6.06---
ASTG09JECBAOTG09JECB6.06---
ASTG12JECBAOTG12JECB6.06---
ASTG18JVCAAOTG18JVCA6.00---
ASTG24JFCCAOTG24JFCC5.02---
ASTG30JFCCAOTG30JFTC5.97---
ASTG34JFCCAOTG34JFTC8.70---
ASTG - Inverter Wall Mounted - Reverse Cycle - R410A
ASTG09LVCCAOTG09LVCC5.565.4922.175°C
ASTG12LVCCAOTG12LVCC6.065.9127.235°C
ASTG18LVCCAOTG18LVCC6.005.9814.805°C
ASTG22LVCCAOTG22LVCC6.005.9814.800°C
ASTG24LFCCAOTG24LFCC5.025.1418.160°C
ASTG30LFCCAOTG30LFTC5.976.0722.500°C
ASTG34LFCCAOTG34LFTC8.708.8026.350°C
ASTG - Designer Range - Reverse Cycle - R410A
ASTG09LUCBAOTG09LUCB5.565.4922.175°C
ASTG14LUCBAOTG14LUCB6.065.9127.235°C
ASTG18LUCBAOTG18LUCB6.005.9814.805°C
AGTV - Inverter Floor Models - Single Phase - R410A
AGTV09LACAOTV09LAC11.1110.9830.845°C
AGTV14LACAOTV14LAL10.6610.6026.135°C
ABTG / ABTF / ABTA - Floor, Floor/Ceiling and Under Ceiling - R410A
ABTG18LVTAAOTG18LACC7.909.7022.720°C
ABTG24LVTCAOTG24LATC10.8010.9023.570°C
ABTF18LATAOTA18LACL / AOTA18LALL12.3112.2228.805°C
ABTF24LATAOTA24LACL / AOTA24LALL12.1012.1829.725°C
ABTA30LBTAOTA30LFTL / AOTA30LGTL11.1111.2023.715°C
ABTA36LATAOTA36LCTL10.4910.4828.030°C
ABTA45LATAOTA45LCTL10.4910.4828.030°C
ABTA54LCTUAOTD54LBTT18.7118.7144.15-5°C
ABTG54LRTAAOTG54LATT17.3917.3839.8720°C
ARTG / ARTA - Ducted - R410A
ARTG09LLLBAOTG09LBCA12.4812.1642.635°C
ARTG12LLLBAOTG12LBCA12.4812.1642.635°C
ARTG18LLTAAOTG18LACC7.909.7022.720°C
ARTG24LMLCAOTG24LATC10.8010.9023.570°C
ARTA30LBTUAOTA30LGTL10.5810.6823.595°C
ARTA36LATUAOTA36LCTL10.5910.5828.135°C
ARTA45LATUAOTA45LCTL10.5910.5828.130°C
ARTG - High Static Ducted - Single Phase - R410A
ARTG30LHTAAOTG30LATL10.1910.1927.6420°C
ARTG36LHTAAOTG36LATL10.1910.0927.6420°C
ARTG45LHTAAOTG45LATL10.4610.3527.9020°C
ARTG54LHTCAOTG54LCTL10.6310.6145.5520°C
ARTG60LHTBAOTG60LATA9.389.3645.5520°C
ARTG / ARTC - High Static Ducted - Three Phase - R410A
ARTG36LHTBAOTG36LATT17.6917.6740.1720°C
ARTG45LHTBAOTG45LATT17.4817.4639.9620°C
ARTG54LHTBAOTG54LATT17.4817.4639.9620°C
ARTG60LHTAAOTG60LATT17.4817.4639.9620°C
ARTC72LATUAOTA72LALT44.1441.9045.67-5°C
ARTC90LATUAOTA90LALT44.1441.9045.67-5°C
AUTG / AUTA - Cassette - R410A
AUTG18LVLAAOTG18LACC7.909.7022.720°C
AUTG24LVLCAOTG24LATC10.8010.9023.570°C
AUTA30LBLUAOTA30LGTL10.7610.8623.465°C
AUTA36LCLUAOTA36LCTL10.5910.5828.130°C
AUTA45LCLUAOTA45LBTL10.5910.5828.130°C
AUTA54LCLUAOTD54LBTT19.0119.0144.4520°C
AUTG54LRLAAOTG54LATT17.6917.6740.1720°C
AOTG - Inverter Multi - Single Phase - R410A
AOTG24LAT3-13.1613.0929.500°C
AOTG24LAT3-13.1613.0929.500°C
AOTG30LBTA4-14.4614.3735.400°C
VRF - J-IIS Outdoor Units - Single Phase - R410A
-AJT040LCLAH33.9934.2832.9060°C compressor temperature
-AJT045LCLAH33.8234.0933.1060°C compressor temperature
-AJT054LCLAH34.0933.9932.9060°C compressor temperature
VRF - J-II Outdoor Units - Single Phase - R410A
-AJYA36LALH45.3045.4638.6060°C compressor temperature
-AJYA45LALH45.3045.4638.6060°C compressor temperature
-AJYA54LALH45.3045.4638.6060°C compressor temperature
VRF - V-II Outdoor Units - Three Phase - R410A
-AJYA72LALH68684660°C compressor temperature
-AJYA90LALH63634660°C compressor temperature
-AJY126LALH1001007860°C compressor temperature
VRF - VR-II Outdoor Units - Three Phase - R410A
-AJTA72GALH1111118960°C compressor temperature
-AJTA90GALH1111118960°C compressor temperature
-AJT108GALH1111118960°C compressor temperature
-AJT126GALH1111118960°C compressor temperature
Reference note: Values are model-specific. Do not apply the standby or pre-heat value from one model to another unless the exact model combination is listed above.