Availability | Support by UTY-VTG*/UTY-VTG*V | Support by BACnet Gateway | ||||||
Monitor | Control | When connecting to 2w R/C line | When connecting to 3w R/C line | Software package (UTY-ABGXZ1) | Hardware package (UTY-VBGX) | |||
For End Users | Basic | Operation on/off | A | A | ok | ok | Same as UTY-VTGX | Same as UTY-VTGX |
Opertion mode | A | A | ok | ok | Same as UTY-VTGX | Same as UTY-VTGX | ||
Setpoint temperature | A | A | ok (in unit of 0.5deg) | ok (in unit of 1deg) | Same as UTY-VTGX | Same as UTY-VTGX | ||
Fan | A | A | ok | ok | Same as UTY-VTGX | Same as UTY-VTGX | ||
Vane direction | Vertical | A | A | ok | not supported | Same as UTY-VTGX | Same as UTY-VTGX | |
Horizontal | A | A | ok | not supported | Same as UTY-VTGX | Same as UTY-VTGX | ||
Room sensors | Intake temperature (R/C) | A | NA | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | |
Special operation status | A | NA | ok | not supported | Same as UTY-VTGX | not supported | ||
Indoor economy operation | A | A | ok | ok | Same as UTY-VTGX | not supported | ||
Anti-freeze operation | A | A | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | ||
Filter sign status/reset | A | A | ok | ok | Same as UTY-VTGX | Same as UTY-VTGX | ||
For Administrators | Restirictions | R/C prohibition | A | A | ok | ok (ON prohibit not supported) | Same as UTY-VTGX | Same as UTY-VTGX |
Emergency stop status | NA | A | Operation stop for emergency stop | Operation stop for emergency stop | Emergency stop can be sent | not supported | ||
Economy saving | Temperature setpoint limit | A | A | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | |
Outdoor capacity save | A | A | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | ||
Forced thermo off | A | A | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | ||
Outdoor low noise operation | A | A | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | ||
Power | Electricity charge apportionment | A | NA | not supported | not supported | Same as UTY-VTGX | Same as UTY-VTGX | |
Option | Model name display | A | NA | Model name for convertor | Model name for convertor | not supported | not supported | |
Error monitoring | Error state, code | A | NA | ok | ok (5U.1 only for some model) | Same as UTY-VTGX | Same as UTY-VTGX | |
System clock | NA | A | ok | not supported | not supported | not supported | ||
Note1. "A"/"NA" in the Availability fields meaning the feature is either available or not available for each monitoring and control. | ||||||||
Note2. Feature not supported by UTY-VTG* is not supported by UTY-ABGXZ1/VBGX. | ||||||||
Note3. For the correspoinding object for each features supported, refer to the Interface Specification of BACnet Gateway. |
BACnet Gateway Hardware - List of Control and Monitoring points for Standard FGA Products Print
Modified on: Fri, 20 Jul, 2018 at 8:25 AM
Did you find it helpful? Yes No
Send feedbackSorry we couldn't be helpful. Help us improve this article with your feedback.