As problem of title, I have received the problem report from quality assurance department.
I would like to inform about problem report detail.
- Problem detail
Product : AOTG18LVCC
Quantity: 145 units
Problem contents :
As to this product, fuse warranty has occurred many times. each product had been send from factory by same lot.
So, FGNZ checked stock product which had been send by same lot. Then, they found wiring mistake by factory.
- Analysis result.
1)Heat run check record at Factory
There was no problem. but, heat run check cannot find this mistake.
Because, when heat run check is carrying out, the current value is approximately 3.7A.
Therefore, the possibility that fuse(F100) is broken in heat run check is nothing.
And more, if compressor frequency is low, the fuse(F100) is not broken even if there is wiring mistake like this time.
2)Patrol inspection at factory
Factory worker had checked cable colour only. (they had not checked cable thickness.
3)Sampling inspection at factory
Visual inspection method is same as Patrol inspection. Operation inspection had carried out, but, could not find, because run time was short and current value was also low(2.1A).
4)Manufacture record
Date ; 19th July 2014
Factory line; D line
Quantity ; 145 units
5)Manufactured record of similar product at same time.
Below is manufactured record which was manufactured at the same time.
We checked, but, wiring mistake is nothing at below product lot.
Product |
Line code |
Quantity |
Manufactured date |
Serial number |
AOTG22LVCC |
B |
35 |
2014.7.25 |
E004546 to E004580 |
AOTG24LFCC |
B |
55 |
2014.7.25 |
E025389 to E025443 |
- Speculation of this result’s cause.
Cause of generation ; factory worker’s mistake
Cause of outflow ; This was circuit which cannot find by heat run check process at factory. - Measure
Improve work instruction document ; Add to check process of wire thickness and presence or absence of sleeve.(Appendix 1)
Improve check sheet of patrol inspection ; Add to check process of thickness of lead cable.(Appendix 2)
Carried out the training by using improve document for factory reader and worker.(Appendix 3) - Measure to product
Already installed product; ; measures by each location if problem is occur.
Stock product; no measures.
Manufacture product ; already measured