General Assist Product and Sales Reference

Sales Promotion Solution — AIRSTAGE VR-II Lineup

Heat-recovery VRF for simultaneous cooling and heating
Outdoor systems from 8 HP to 48 HP with a broad indoor-unit lineup for commercial applications
The AIRSTAGE VR-II is a heat-recovery VRF system designed to provide simultaneous cooling and heating across multiple zones. Its modular outdoor-unit range and extensive indoor-unit selection support flexible system design for medium and large commercial projects.

1. Product overview

The AIRSTAGE VR-II combines heat-recovery operation with a scalable VRF platform. It is suited to buildings where different rooms or zones may require heating and cooling at the same time.

FeatureVR-II Lineup
System typeHeat-recovery VRF with simultaneous cooling and heating
Outdoor range34 system models
Capacity range8 HP to 48 HP, approximately 22.4 kW to 135.0 kW
Indoor range12 types and 55 models
Indoor capacity range2.2 kW to 25.0 kW

2. Outdoor-unit lineup

The outdoor range is grouped into three principal capacity bands.

8 / 10 / 12 HP
Single-module options for lower-capacity commercial applications.
14 / 16 HP
Higher-capacity single-module options for moderate building loads.
18–48 HP
Modular combinations for larger projects and extensive zoning requirements.
Design flexibility: The lineup identifies both space-saving and energy-efficiency combinations. The appropriate combination should be selected against project capacity, installation footprint and efficiency priorities.

3. Indoor-unit lineup

The VR-II platform supports a wide selection of indoor-unit styles, allowing the system design to be matched to room layout, ceiling space, airflow requirements and architectural preferences.

CategoryAvailable stylesTypical design benefit
Cassette4-way compact cassette and 4-way cassetteBroad air distribution from a ceiling-mounted unit
Concealed ductLow static, slim duct, medium static and high staticDiscreet installation with adaptable duct design
FloorFloor standing, concealed floor mounted and slim concealed floor mountedUseful where ceiling installation is restricted
CeilingCeiling-mounted typeExposed installation without occupying floor area
Wall mountedStandard wall-mounted and compact wall-mounted stylesSimple installation for smaller rooms and individual zones

4. Distinctive system advantages

Simultaneous comfort
Heat-recovery operation allows one zone to cool while another zone heats, helping the system respond to different room loads within the same building.
Scalable system design
The 8–48 HP range supports both single-module and combined-module systems, providing a practical pathway from moderate-capacity projects through to large multi-zone installations.
Broad indoor compatibility
Twelve indoor-unit types and 55 models allow designers to select units by room function, available ceiling space, required static pressure and appearance.
Heat-recovery efficiency
Where heating and cooling demands occur simultaneously, heat can be transferred within the refrigerant network rather than rejected entirely, supporting more efficient operation than separate heating and cooling processes.

5. Sales promotion messaging

Sales themeCustomer message
Simultaneous comfortDifferent zones can be heated and cooled at the same time from one integrated VRF system.
System scalabilityThe modular outdoor lineup supports projects from 8 HP through to 48 HP.
Architectural flexibilityA wide indoor-unit range supports exposed, concealed, ceiling, wall and floor applications.
Design choiceSpace-saving and energy-efficiency combination options help align the system with project priorities.
Operational efficiencyHeat recovery can reuse energy between zones where simultaneous heating and cooling demands exist.

Typical target applications

  • Commercial offices and multi-tenant buildings
  • Hotels and hospitality facilities
  • Education and healthcare buildings
  • Mixed-use developments with varying zone loads
  • Projects requiring a combination of concealed and exposed indoor-unit styles

6. Recommended promotional support

  • Outdoor-unit combination charts showing space-saving and energy-efficiency options
  • Indoor-unit selection guides arranged by type, capacity and available static pressure
  • Application examples demonstrating simultaneous heating and cooling
  • Project case studies for offices, hotels and mixed-use buildings
  • Installer and commissioning training covering refrigerant design, controls and heat-recovery configuration
Important: Final equipment selection, allowable combinations, connected-capacity limits, piping design and control compatibility must be confirmed against the applicable engineering data, design software and current installation documentation.
VR-II sales summary